CTI Products EXB Network Manager User Manual

Page 28

Advertising
background image

Hot-Standby EXB / Network Manager Software Manual

Network Manager

CTI Products, Inc.

Program Operation

24

68-11707-100

Yellow Switch

(Standby EXB only)
The Standby EXB is not receiving a
Holdoff command and has turned its
network switch on.

Line Name

WAN Line Name for the Main (top) or Standby (bottom)
EXB as defined in the database. This is typically a
telephone microwave or T1 line number which can be used
to troubleshoot the system.

Line Status

Status of the WAN Line for the Main (top) or Standby
(bottom) EXB as determined by the program

Green OK

Functioning Properly

Red Error

Line bad

Gray ???

There is a problem but the program
doesn't have enough information to
determine the true status of the line

Remote EXB Name Shows the Remote EXB names as defined in the database.

The top name in a pair of rows is the Remote Main EXB.
The bottom name is the Remote Standby EXB.

Remote EXB Status Shows the status of the Remote EXBs.

The top status is for the Remote Main EXB.
The bottom status is the Remote Standby EXB.

Green OK

Functioning Properly

Red Failed

Program cannot talk to EXB

Gray ???

There is a problem but the program
doesn't have enough information to
determine the true status of the EXB

Remote units do not have the "Switch" function.

JMP (Right)

Shows the status of the Remote MCN Tie lines.
Same status indications as the JMP (Left) column.

Remote Site Name Shows the Remote Site Name as defined in the database.

There may be multiple EXB channels to a particular remote
site, serving various radio channels, depending upon the
network configuration.

MCN Group

MCN Group Number for the CIBs attached to this EXB
channel, as defined in the database.