Otal outputs, Otal, Utputs – CTI Products OTAL On-the-Air Driver Assembly User Manual
Page 11
![background image](/manuals/334840/11/background.png)
CTI Products, Inc.
OTAL Driver Assembly User Guide
The Remote COR signals appear on the following pins of J1 of the remote COR CIB module as follows:
Remote COR CIB J1
Wire Color
CIB Function
OTAL System Function
1 Blu/Wht
Ground
Ground-Common
22
Org/Vio
Rx 1
COR 1 input
47
Vio/Org
Rx 2
COR 2 input
16
Blu/Yel
Rx 3
COR 3 input
41
Yel/Blu
Rx 4
COR 4 input
10
Slt/Red
Rx 5
COR 5 input
35
Red/Slt
Rx 6
COR 6 input
4
Brn/Wht
Rx 7
COR 7 input
29
Wht/Brn
Rx 8
COR 8 input
OTAL
O
UTPUTS
The OTAL outputs are opto-isolated solid state relays. They are active in the closed position. These outputs
appear on the last 8 pairs of J1 of the OTAL Driver Assembly as follows:
OTAL Driver Assembly J1
Wire Color
Signal
43
Yel/Grn
OTAL Ry 1+
18
Grn/Yel
OTAL Ry 1-
44
Yel/Brn
OTAL Ry 2+
19
Brn/Yel
OTAL Ry 2-
45
Yel/Slt
OTAL Ry 3+
20
Slt/Yel
OTAL Ry 3-
46
Vio/Blu
OTAL Ry 4+
21
Blu/Vio
OTAL Ry 4-
47
Vio/Org
OTAL Ry 5+
22
Org/Vio
OTAL Ry 5-
48
Vio/Grn
OTAL Ry 6+
23
Grn/Vio
OTAL Ry 6-
49
Vio/Brn
OTAL Ry 7+
24
Brn/Vio
OTAL Ry 7-
50
Vio/Slt
OTAL Ry 8+
25
Slt/Vio
OTAL Ry 8-
The solid-state relay outputs listed above are polarity-sensitive, and are current-limited to 0.5A. Typical lamp
connections are shown below.
Figure 5 – Typical Lamp Connections
Field
Connections
11