Field connections, Local ptt connections, Ocal – CTI Products OTAL On-the-Air Driver Assembly User Manual

Page 9: Onnections, Ield

Advertising
background image

CTI Products, Inc.

OTAL Driver Assembly User Guide

F

IELD

C

ONNECTIONS

L

OCAL

PTT

C

ONNECTIONS

Local PTT signals are connected to J1 of the OTAL Driver PCB. (PTT inputs are not required if COR Only
OTAL Logic is used.)

Local PTT signals shall be either:

ƒ Isolated Form A Relay Contacts (or opto-isolated relay outputs)

closed when PTT signal is present.

ƒ Logic Outputs - Negative Ground, Active Low when PTT is active.

They must be capable of:

ƒ Up to +20 VDC Open Circuit

ƒ Sinking a minimum of 30 mA when active

ƒ Maximum of 0.2 V when active

Signals must not drive other equipment.

The Local PTT signals appear on the first 8 pairs of J1 as follows:

OTAL J1

Wire Color

Signal

1 Blu/Wht

PTT

1A

26 Wht/Blu

Gnd

1A

2 Org/Wht

PTT

2A

27 Wht/Org

Gnd

2A

3 Grn/Wht

PTT

3A

28 Wht/Grn

Gnd

3A

4 Brn/Wht

PTT

4A

29 Wht/Brn

Gnd

4A

5 Slt/Wht

PTT

5A

30 Wht/Slt

Gnd

5A

6 Blu/Red

PTT

6A

31 Red/Blu

Gnd

6A

7 Org/Red

PTT

7A

32 Red/Org

Gnd

7A

8 Grn/Red

PTT

8A

33 Red/Grn

Gnd

8A

(The “A” suffix on the PTT signals indicates the Local PTT.)

The ground signals are tied together on the OTAL Driver board. It is preferred that the PTT signals be wired to
J1 as pairs, with separate grounds.

Field

Connections

9