Installing the 455 d control panel, 455 d c – Controlled Products Systems Group 104470 User Manual

Page 10

Advertising
background image

Page 10

January, 200 4

412 O pe rator And

455 D Control Panel I nst allatio n M anual

I

NSTALLING

THE

455 D C

ONTROL

P

ANEL


Locate the control panel enclosure in the most

convenient position possible, considering the movement
of the gate. Figure 12 shows a basic layout for a two-
leaf gate with the 412 Compact Operator.


Installing the control panel consists of the following
general steps:

Connecting the main power to the control
panel

Connecting the activating device

Connecting the operator to the control panel

Checking the direction of the motor's rotation

Connecting other devices to the control panel

Set operating modes


The installer is responsible for grounding the gate and
operator systems, for providing the main power breaker

switch, and for making sure that the entire gate system
meets all applicable electrical codes.

For the complete 455 D Control Panel Installation
Instructions, see pages 14—25 of this manual.

A

TTACH

THE

O

PERATOR

C

OVER

.


Once the operator is attached to the gate leaf, you
next prepare the cover for installation.

Caution: If you did not correctly establish the
orientation of the gate leaf and properly
install the DX model on the right side and SX
on the left side, you will be unable to install
the cover on either operator.

Position the mounting insert inside the aluminum
cover and then slide the aluminum cover into
position. Secure the cover and insert with the short
screws provided (see Figure 11).

4 3/8 in.

(11 cm)

2 3/4 in.

(7 cm)

Figure 8. Attach the operator to the rear

mounting bracket (an SX version is shown)

Minimum of 3 1/8 in. (8 cm) from
the back of the vertical mounting
plate to the center of the front
mounting hole on the operator

Figure 9. Secure the operator to the front mount-

ing bracket with the short pin and 2 snap rings

Figure 10. Weld the front mounting bracket into position

after insuring the operator is level in the fully closed and

fully opened positions

The plastic cover insert
has a slot that must align
with the slot in the cover

End cap for cover

Figure 11. Attach the cover with two screws (SX

model shown)

Advertising
This manual is related to the following products: