Connect other devices, 455 d c, Ontrol – Controlled Products Systems Group 104470 User Manual

Page 16: Anel, Nstallation, Nstructions, Onnect, Ther, Evices

Advertising
background image

NOTE: In order to c omply with UL 325, two s ets
of FAAC photobeams mus t be ins talled. One s et
s hould be 6 in. outs ide the c los ed gate(s ) and ac t
as a c los ing rev ers ing dev ic e. Another s et s hould
be 6 in. bey ond the s wing of the gate(s ) and ac t
as an opening rev ers ing dev ic e. The ins taller is
res pons ible for determining the appropriate
mounting height.

22 23 24 25

1

2

3

4

5

6

7

8

N

L

9

10 11 12 13 14 15 16 17 18 19

115 V A C +/- 10%

or

230 V A C +6/ -10%

50-60 Hz

20 21

-

S TOP

OP E N

OP E N

(1 of 2)

24V

+

FS W

OP

C L

-

FS W

-

-

+

W .LIGHT

24 vdc

3 W

LOCK

E LE CTRIC LOCK

1

2

1

2

3

4

5

1

2

3

4

5

1

2

FS W OP

FS W CL

Other safeties

LA MP

BL

U

E

MOTOR 1

C 1

M1

OP

C OM

C L

BL

U

E

MOTOR 2

C 2

M2

OP

C OM

C L

Page 16

January, 200 4

412 O pe rator And

455 D Control Panel I nst allatio n M anual

Figure 14.

The terminal strip wiring of

the 455 D with photobeams

You cannot check the motor’s direction of rotation
without these circuits (jumpers) or the accessories.

When properly prepared for testing, the LEDS FSWOP,
STOP, and FSWCL should be illuminated (see figure 16
on page 17).

WARNING!

Running the operator—even for

testing purposes—without a connected reversing
device is potentially dangerous. Do not place
yourself within the path of the moving gate

during your test.

Disengage the operator(s) with the Manual Release

key (see operator installation manual), and open the
gate by hand about halfway.
Next, engage the operator(s) with the Manual Release

key so that you can check the rotation of the motor
(s).

To activate the operator(s) momentarily short across
terminals 9 and 14.


Turn on the main power and send an activating signal
to the operator. The gate leaf (or leaves) should open.

If a gate leaf closes, then you need to turn off the
main power and reverse the connection of the red
and black wires on terminal block J4 for the operator

controlling that leaf. Then you need to recheck the
rotation direction again.

After having completed your test of the motor’s
direction of rotation, replace any test circuits you
installed (between terminals 11 and 16, between 12

and 19, and between 13 and 19) with the proper
reversing and stop devices. The instructions for
installing such accessories follow.

C

ONNECT

O

THER

D

EVICES


WARNING! Turn the main power off before you
make any electrical connections.

P

OWER

S

UPPLY

FOR

A

CCESSORIES

: You can access a 24

VDC output for supplying power to accessories
through terminals 17 or 18, (+) and 14 or 15 or 16, (-

) on terminal block J1. In most cases, this source can
be used to power 24 VDC accessories.

N

OTE

: The 455 D control panel allows a

maximum accessory load of 800 mA.

R

EVERSING

D

EVICES

:

Reversing devices include

photocells, inductive loops, and so forth. All of the
reversing devices should have contacts of the
normally closed (N.C.) type. Where you connect a

device depends on whether you want the device to
operate during opening or during closing.

N

OTE

: UL does not recognize the FAAC system

with loop detectors or safety edges. FAAC

photobeams must be used to comply with UL
325.

To wire photobeams, refer to page 19 (see FSWOP for
opening photobeams, and FSWCL for closing
photobeams). Photobeams must be connected as

shown. See also page 19 for the wiring of inductive
loops. If using more than one reversing device, they
must be wired in series.

T

HE

455 D C

ONTROL

P

ANEL

I

NSTALLATION

I

NSTRUCTIONS

Advertising
This manual is related to the following products: