624 bld c, Ont r ol, Ane l – Controlled Products Systems Group 10463283 User Manual

Page 30: Ns ta lla t io n

Advertising
background image

P a g e 3 0

Ja nua ry , 2 00 7

6 2 0 /6 40 O pera tor And

6 2 4B LD C ontr ol Pa ne l Ins tal la tion M a nual

T

HE

624 BLD

C

ONT

R

OL

P

ANE

L

I

NS

TA

LLA

T

IO

N

I

NS

T

R

U

C

T

IONS

2ND LEVEL PROGRAMMING continued

DISPLAY FUNCTION DEFAULT

OUTPUT

1

POLARITY:

For configuring the output

polarity status.

= N.C. polarity

= N.O. polarity

NOTE: If the output is set to

FAIL-SAFE (00) leave the default

value.

OUTPUT

2:

See output 1

OUTPUT

2

POLARITY:

See Output 1 Polarity.

OUTPUT

3:

See output 1

OUTPUT

3

POLARITY:

See Output 1 Polarity.

OUTPUT

4:

See output 1, except to functions

00, 11, 12 that in this case have

no effect.

OUTPUT

4

POLARITY:

For configuring the output

polarity status.

= Active

= Excluded

ASSISTANCE REQUEST (work with

the next two functions):

If activated at the end of the

count-down (settable with the

next two functions under “Cycle

Programming”), it activates LAMP

output for 4 sec every 30 sec.

Can be useful for setting

scheduled maintenance.

= Active

= Excluded

2ND LEVEL PROGRAMMING continued

DISPLAY FUNCTION DEFAULT

FAIL

SAFE:

If this function is activated, it

enables a function test of the

photocells before any automated

system movement, independently

from the output used. If the test

fails, the automated system does

not start the movement.

= Active

= Excluded

OUTPUT

1:

The output can be set to one of

the following functions:

FAILSAFE

I N D I C A T O R L I G H T

(lighted at opening and

pa use , fla sh i n g at

closing, and off when

a u t o m a t e d s y s t e m

closed)

BEAM LIGHT (output

achieve with beam closed

and on pause, inactive

with beam open, flashing

during movement)

BEAM CLOSED

BEAM OPEN or in PAUSE,

it goes OFF during

closing pre-flashing

B E A M M O V I N G A T

OPENING, pre-flashing

included

B E A M M O V I N G A T

CLOSING, pre-flashing

included

BEAM STILL

BEAM IN EMERGENCY

STATUS

LOOP 1 ENGAGED

LOOP 2 ENGAGED

OPEN FOR 624 SLAVE

CLOSE FOR 624 SLAVE

BEAM DETACHED

Advertising