20
© 2012 Installation and Reference Manual D0119 Rev. J
Section 3
— Wiring Control Inputs
1. Test the open and close function of the gate before wiring to accessory devices (external control inputs). This makes it
easier to troubleshoot if an unexpected functionality arises. The Smart Touch Controller has a tact button you can
push which lights an LED next to the active inputs. This button is in bottom left corner of the Smart Touch Controller
board.
2. All the Smart Touch Controller inputs listed below are shown as a single input. The second wire is connected to the
Common Terminal Bus (COM) on the Smart Touch Controller.
NOTE: The Emergency Close and Fire Dept. Open inputs are an exception and require a +24V input. The +24V is
located on the spade terminals next to the Common Bus. Refer to the photograph on the next page.
Smart Touch Controller Inputs
1.
*Stop Push button N.C. input, jumper to Common if unused
2.
*Open Push Button Not for radio or remote access controls
3.
*Close Push button Not for radio or remote access controls
4.
Remote Open & Radio Control For radio / remote open device
–
Program to Close using Smart Touch Controller keypad
5.
Open/Close button Pushbutton or radio controls
6.
Partial Open Installer adjustable from 7- 99 seconds
7.
Open interlock input or Time clock Open programmable
8.
Free Exit vehicle detector
9.
Disable Free Exit vehicle detector or Timer to Close
Free Exit is only disabled if Close Limit Switch is tripped. If the gate is
partially opened, the Free Exit detector will trigger the gate to open fully.
10.
Inside Obstruction vehicle detector Inside reversing loop
11.
Outside Obstruction vehicle detector Outside reversing loop
12.
Shadow/Reset vehicle detector Shadow function used for Swing
gates only - Reset function is for Arm gates
13.
Edge Sensor One input works for both travel directions
14-15.
Photo eye Common Power
24V common connection for open and close photo eyes
17.
Photo eye Open direction
19.
Photo eye Close direction
21.
Charger AC power loss Only used in DC, battery type operators
22.
Spare Input Software
≤ h3.26,- non functional,
Gate Lock Interlock Input Software > h3.26, prevents start until
external gate lock releases
23.
**Emergency Close Must menu enable and input +24 Volts to trigger.
Requires constant hold or maintained input. This overrides photo eyes,
gate edges & vehicle detectors.
24.
**Fire Dept. Open Must menu enable and input +24 Volts to trigger.
Overrides photo eyes, gate edges, and vehicle loops.
CAUTION: *Only connect an external control to terminals #1, 2 or 3 when the controls are located in clear
view of the entire gate area. For controls that need not be in line of sight, use input terminals #4, 5, 6 or 7.
**The Emergency Close and Fire Dept. Open inputs are to be used only if access to these controls is guarded and
supervised.
Tact button