3.2 PROGRAMMING WITH A PC

Prior to programming the PC Programmable Access Control System with the DoorKing Remote
Account Manager for Windows software and the user supplied PC, the system must have the
MASTER CODE programmed into it. The master code cannot be set with the PC and must be
programmed from the system keypad.

NOTE: The programming steps in this section (3.2.1 through 3.2.6) can only be programmed
from the system keypad. There is no programming sequence in the Remote Account Manager
Software for these functions.

3.2.1 Master

Code

This programming step sets the system MASTER CODE. The master code is the four-digit number
required to gain access to the system memory. You need to know the master code prior to
programming the system with the PC, or to perform any of the programming functions on the
following pages.

Factory setting = 9999

1. Open the cabinet of the telephone entry system and turn the master code switch (the

small slide switch) to the on position.

2. Enter a four-digit master code _ _ _ _ then press * (beep).

3. Turn the master code switch off and close the cabinet.

3.2.2

Single or Multiple Systems

This program sequence sets the access control system to operate as a single unit on the phone line,
or to share the phone line with other units. If multiple systems are sharing the same phone line, then
each one must be set as a "multiple system" and each must have a unique master code.

Factory setting = Single System.

1. Press

* 0 4 and then enter the four-digit MASTER CODE _ _ _ _ (beep).

2. Enter

0 * (beep) for a single system or 1 * (beep) for multiple systems.

3. Press

0 # TOGETHER to end this programming step (beeeeeep).


3.2.3

Programming Resident Elevator Button Relay Time

When elevator control is in use, an access device such as a card reader must be installed in the
elevator car to allow residents access to the floors in the building. The time interval that the button(s)
is “live” after the resident activates the access device is dependant on the revision level of the 1838
access controller circuit board, not the 2348 elevator control board. The relay time interval for 1838
circuit boards with revision level A-C is set at 7 seconds. The time interval can be
programmed from 1 – 254 seconds on boards with revision level D and higher.

Factory setting = 007

1. Press

* 3 6 and then enter the four digit master code _ _ _ _ (beep).

2. Enter the relay time in seconds _ _ _ (001-254) then press * (beep).

3. Press

0 # together to end this programming sequence (beeeeeep).