Front indicators, Front controls, Back controls – Controlled Products Systems Group MVPDTEK User Manual

Page 4

Advertising
background image

Front Indicators

1. Green Led is ON - the detector is powered.
2. Red Led is ON - the detector detected a vehicle
3. Green Led is Blinking - the loop failed and is shorted or disconnected
4. Green Led is Blinking with two consecutive fast blinks - the loop failed in
the past and now is working correctly.
5. Red Led is Blinking at the start of a vehicle detection - the Filter function is
ON
6. Red Led is Blinking at the end of a vehicle detection - the Extend function
is ON
7. Red Led is Blinking during a vehicle detection - 4 minute limited presence
time has expired.

Front Controls

Reset

This toggle switch when pushed momentarily down will reset the detector

Frequency Counter

This toggle switch when pushed momentarily up will count the frequency on
the loop. This count is displayed by the Red Led blinks, each blink
represents frequency of 10K Hz. Count between 3 to 13 blinks confirms
that the loop detector is tuned to the loop.

Frequency

This toggle switch controls the loop frequency. Set different frequencies

on adjacent loops. Verify frequencies with the frequency counter by

counting the Red LED blinks.

Back Controls

Sensitivity

This rotary switch controls the detector sensitivity. During normal operation
the sensitivity level is set to 3 or 4.

DIP Switch Functions

(When Dip7 and 8 are in ON position the extend time is 9 seconds.)

Warning:

Do not use limited presence setting and / or "Fail Secure" setting for reversing gates, doors or barriers.

3 seconds

Extend detect

8

6 seconds

Extend detect

7

Automatic Sensitivity Boost On

ASB Off

6

Filter On

Filter Off

5

"Fail Safe"

"Fail Secure"

4

4 minute limited presence time

Constant
presence

3

Pulse on Un-detect

Pulse on detect

2

Presence on Relay II

Pulse on Relay II

1

ON

OFF

DIP

Advertising