Optional peripherals – Impulse AUPS-A10 User Manual
Page 3

w w w . i e i w o r l d . c o m
Optional Peripherals
Model Name
AUPS-A10
AUPS-A20
AUPS-B10
AUPS-B20
AUPS-C20
VESA Type
VESA 75
VESA 75
VESA 75 and 100
VESA 75 and 100
VESA 75 and 100
Input Data
Input voltage Uinated/range
DC +12V
DC +9V~+36V
DC +12V
DC +9V~+36V
DC +9V ~ +36V
Input current rated
1. Adapter is 12V-6A (Load is 60W)
2. Battery is 6V-12A (Load is 60W)
1. Adapter is 12V-9A (Load is 100W)
2. Battery is 12V-9A (Load is 100W)
Standby power consumption
0.3A (0.2A if Network Management disabled)
Operation with charging current
500mA
Operation with charging power consumption
6W
10W
Charging time with system ON/OFF
8hrs / 2hrs (Battery empty)
Output Data
Output voltage for normal operation
DC +12V +/-5%
Output voltage for battery operation(approx). 6~8.4V DC6 V (exhaustive discharge protection)
12~16.8V DC12 V (exhaustive discharge protection)
Output current
0A~5A
0A~8.3A
0A~7.6A
Efficiency (nominal operation) / power loss
at Vin=12V, Iout=80% of full loading
89%
93%
95%
94%
90%
Protection
Short-circuit protection
Yes
Exhaustive discharge protection
1. Battery low is 10% of battery capacity
2. Shuntdown 5% of battery capacity (Default)
3. The end of battery discharge voltage is 6V
EMC / Safety certification
CE, FCC
Monitoring
Ethernet interface
Web-based, specification 10/100Mbps with RJ-45 connection, Cat. 5 cable
USB interface
PC-capable, specification 2.0 with full speed, i.e. 2 Mbit/s. Standard 4-core shielded cable, USB Series "mini B" connector to DC-
UPS
Physical
Dimensions (LxWxH)
152mm x 96mm x 28mm
174mm x 147mm x 35mm
233mm x 197mm x 59mm
Weight
1.2 kg
1.8 kg
3.8 kg
LED Indicator
Green
DC power input
Yellow
Battery charging
Orange
Bettery discharging
Environment
Operating Tem.
0°C~40°C
Storage Tem.
-20°C~50°C
Note1: Connecting DC input constantly is recommended. Battery will be drained after 14 hours.
Note2: System power consumption + AUPS charging power consumption = Total watts of power source
Model Name
AUPS-A10
AUPS-A20
AUPS-B10
AUPS-B20
AUPS-C20
Battery Model Name
BAT-LI-2S2P3800
BAT-LI-4S2P3800
BAT-LI-4S2P3800(x4)
Battery
Battery type
Li-Ion 2S2P 7.4V
Li-Ion 4S2P 14.8V
Li-Ion 4S2P 14.8V
Battery capacity
7.4V 3800 mAH
14.8V, 3800 mAH
14.8V, 3800 mAH(x4)
Maximum charge voltage
8.4V
16.8V
16.8V
The end of discharging voltage
5.6V
11.2V
11.2V
Recommended charging current (max.)
2A
2A
2A
System continuous discharging current (max.)
7.6A
7.6A
7.6A
The end of charge condition
250mA / 1Min
200mA / 1Min
200mA / 1Min
Discharge protection
Under voltage protection / Over current protection
Charge protection
Over voltage protection / Over current protection
Ambient temperature
0°C~40°C
Storage temperature
-20°C~60°C
Self-discharge rate
340uA~440uA
Dimensions (LxWxH)
139mm x 47mm x 26mm
165mm x 76mm x 26mm
165mm x 76mm x 26mm
Weight
236g
450g
450g
Cycle life
300 charge / discharge cycles
Backup
60W / 10Min
100W / 10Min
100W / 10Min
Safety class
CE, FCC
CE, FCC
AFOLUX PPC
AUPS-A10
AUPS-A20
AUPS-B10
AUPS-B20
Under 50W solution
AFL-057-LX (15W~20W)
145min
145min
290min
290min
AFL-07A-N270 (20W~25W)
100min
100min
200min
200min
AFL-08AH-N270 (25W~30W)
70min
70min
140min
140min
AFL-10A-N270 (25~30W)
70min
70min
140min
140min
AFL-10A-9103 (40W~45W)
50min
50min
100min
100min
AFL-10A-LX (25W~30W)
70min
70min
140min
140min
AFL-12A-LX (25W~30W)
70min
70min
140min
140min
AFL-12B-CX2 (38W~42W)
50min
50min
100min
100min
AFL-12A-N270 (25W~30W)
70min
70min
140min
140min
AFL-12B-9103 (45W~48W)
45min
45min
90min
90min
50W ~ 100W solution
AFL-15B-915-CM370 (58W~63W)
-
-
35min
35min
AFL-15C-9652-T7500 (65W~70W)
-
-
30min
30min
AFL-17B-915-CM370 (75W~80W)
-
-
25min
25min
AFL-17C-9652-T7500 (85W~90W)
-
-
20min
20min
AFL-19B-915-CM370 (75W~80W)
-
-
25min
25min
AFL-19C-9652-T7500 (85W~90W)
-
-
20min
20min
BAT-LI-4S2P3800
BAT-LI-2S2P3800
Note: Replacing battery module every 2 years is recommended.
Note: The backup time could be varied on different models or operating temperature.
AUPS Module Specifications
Battery Module Specifications
Optional Peripherals-2012-V10