DB-78 Female Pin Assignment

This table shows the pin assignments via the card edge connector.

Port 1

Port 2

Relay A Side

Relay B Side

Relay A Side

Relay B Side

Relay Port

1

-

A

Pin Port 1 -

B

Pin Relay Port 2 -

A

Pin Port

2

-

B

Pin

K1 1 2 1 20

K9 1 10 1 28

K2 2 3 2 21

K10 2 11 2 29

K3 3 4 3 22

K11 3 12 3 30

K4 4 5 4 23

K12 4 13 4 31

K5 5 6 5 24

K13 5 14 5 32

K6 6 7 6 25

K14 6 15 6 33

K7 7 8 7 26

K15 7 16 7 34

K8 8 9 8 27

K16 8 17 8 35

Port 3

Port 4

Relay A Side

Relay B Side

Relay A Side

Relay B Side

Relay Port

3

-

A

Pin Port 3 -

B

Pin Relay Port 4 -

A

Pin Port

4

-

B

Pin

K17 1 39 1 57

K25 1 47 1 65

K18 2 40 2 58

K26 2 48 2 66

K19 3 41 3 59

K27 3 49 3 67

K20 4 42 4 60

K28 4 50 4 68

K21 5 43 5 61

K29 5 51 5 69

K22 6 44 6 62

K30 6 52 6 70

K23 7 45 7 63

K31 7 53 7 71

K24 8 46 8 64

K32 8 54 8 72


Power and Ground Pin Assignments

Via DB-78 Female card edge connector.

Ground

18, 36, 37, 55, 73, 74

+ 5 Volts

19, 56

+ 12 Volts

1, 38