Overview
The Sealevel Systems COMM+8 provides the PC with eight RS-232
asynchronous ports. The COMM+8 allows for connection to any device
utilizing the RS-232 electrical interface, such as modems, data-entry terminals,
and plotters.
What’s Included
The COMM+8 is shipped with the following items. If any of these items is
missing or damaged, contact the supplier.
• COMM+8 Serial I/O Adapter
• “Octopus” Cable providing 8 DB-25 or DB-9 connectors
• Sealevel Software
Factory Default Settings
The COMM+8 factory default settings are as follows:
Port #
Base Address
IRQ
E12
Port 1
280
5
DIV4
Port 2
288
5
Port 3
290
5
Port 4
298
5
Port 5
2A0
5
Port 6
2A8
5
Port 7
2B0
5
Port 8
2B8
5