Laurel Electronics LT: 4-20 mA & Serial Data Output Transmitter for Average Time of Periodic Events User Manual

Page 2

Advertising
background image

LAUREL

ELECTRONICS INC.

, 3183-G Airway Ave., Costa Mesa, CA 92626, USA • Tel 714-434-6131 • www.laurels.com 2

Specifications

Pulse Input

Signal Types
Signal Ground
Minimum Signal
Maximum Signal
Maximum Frequency
Contact Debounce
Time Base Accuracy
Span Tempco
Long-term Drift

AC, pulses from NPN, PNP transistors, contact closures, magnetic pickups
Common ground for channels A & B.
Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V).
250 Vac
1 MHz, 30 kHz, 250 Hz (selectable).
0, 3, 50 ms (selectable).
Quartz crystal calibrated to ±2 ppm.
±1 ppm/°C (typ)
±5 ppm/year

Time Interval Mode

Timing Start
Timing Stop
Update Rate
Gate Time
Time Before Zero Output

Channel A pulse, + or - edges
Channel B pulse, + or - edges
Gate time + 30 ms + 0-2 time intervals
Selectable 10 ms to 199.99 s
Selectable 10 ms to 199.99 s

Resolution

0 - 199.999 s
0 - 99.9999 s
0 - 9.99999 s
0 - .999999 s
0 - .099999 s

1 ms
100 µs
10 µs
1 µs
0.2 µs (after averaging)

Analog Output (standard)

Output Levels
Compliance, 4-20 mA
Compliance, 0-10V
Output Resolution
Output Accuracy
Output Update Rate
Output Isolation

4-20 mA and 0-10 Vdc (selectable)
10V ( 0-500Ω load )
2 mA ( 5 kΩ load )
16 bits (65,536 steps)
±0.02% of output span
Programmed gate time + 30 ms + 0-2 signal periods
250V rms working, 2.3 kV rms per 1 minute test

Serial Data Output (standard)

Signal Types
Data Rates
Output Isolation
Serial Protocols
Modbus Compliance
Digital Addressing

RS232 or RS485 (half or full duplex)
300, 600, 1200, 2400, 4800, 9600, 19200 baud
250V rms working, 2.3 kV rms per 1 min test
Modbus RTU, Modbus ASCII, Laurel ASCII
Modbus over Serial Line Specification V1.0 (2002)
247 Modbus addresses. Up to 32 devices on an RS485 line with no repeater

Transducer Excitation Output (standard)

Jumper Selection 1
Jumper Selection 2
Jumper Selection 3

10V @ 60 mA, isolated to 50V from signal ground
5V @ 50 mA, isolated to 50V from signal ground
15V @ 60 mA, non-isolated

Power Input

Standard Power
Low Power Option
Power Frequency
Power Isolation
Power Consumption

85-264 Vac or 90-300 Vdc (DC operation not UL approved)
10-48 Vdc or 12-32 Vac
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test
2W typical, 3W with max excitation output

Mechanical

Dimensions
Mounting
Electrical Connections

129 x 104 x 22.5 mm case
35 mm rail per DIN EN 50022
Plug-in screw-clamp connectors

Environmental

Operating Temperature
Storage Temperature
Relative Humidity
Cooling Required

0°C to 55°C
-40°C to 85°C
95% at 40°C, non-condensing
Mount transmitters with ventilation holes at top and bottom.
Leave 6 mm (1/4") between transmitters, or force air with a fan.

Advertising