Laurel Electronics LTE SERIES TRANSMITTERS ANALOG INPUT User Manual

Page 22

Advertising
background image

- 22 -

12. LOAD CELL SIGNAL CONDITIONER BOARD JUMPER SETTINGS

Five ranges are jumper selectable. These also have to be selected in Instrument Setup software.

1. Use 2.5 mm (0.1") jumpers

.

2. Store spare jumpers on an unused jumper post.



13. THERMOCOUPLE SIGNAL CONDITIONER BOARD JUMPER SETTINGS

Seven thermocouple types are jumper selectable. These also have to be selected in Instrument
Setup software.

Board Revision A

1. Use 2.5 mm (0.1") jumpers.
2. Store spare jumpers on an unused jumper post.

Load Cell & Microvolt Ranges

FS Input

Jumpers

±20.000 mV
±50.000 mV
±100.00 mV
±250.00 mV
±500.00 mV

e
a
b

c

d

Thermocouple Type

E4 Jumper

J, K, E, N
T, R, S

none

j

Open T/C Indication

E3 Jumper

Upscale
Downscale

h

i

h

i

j

E4

E3

3
4

1
2

PNP transistor

J5-X

J5-Y

c + b

e

- Sig
+ Sig

Advertising