Laurel Electronics LAUREATE SERIES SCALE-WEIGHT METER User Manual

Page 35

Advertising
background image

35

20. SCALE METER SPECIFICATIONS

Meter Display

Type ....................................5 LED, 7-segment, 14.2mm (.56") high digits & 3 LED indicators
Color....................................................................................................................Red or green
Range.................................................................... -99999 to +99999 and -99990 to +99990

A to D Conversion

Technique (Pat.5,262,780)........................................................................ Concurrent Slope

TM

Read Rate ............................................................... 60/s for 60 Hz NMR, 50/s for 50 Hz NMR
Output Update Rate .....................................................................56/s at 60 Hz, 47/s at 50 Hz
Display Update Rate .....................................................................3.5/s at 60 Hz, 3/s at 50 Hz

Noise Rejection

CMV from DC to 60 Hz................................................................................Withstand 250Vac
Dielectric strength....................................................... 3.5 kV ac for 5 sec, 2.3 kV ac for 1 min
CMR from DC to 60 Hz ................................................................................................ 130 dB
NMR at 50/60 Hz...............................................................90 dB with minimum digital filtering

Control Inputs (CMOS/TTL levels, logic 0 = tied to digital ground, logic 1 = open)

/ Hold input ..........................................................................Logic 0 holds display and outputs
/ Peak ........................................................................................... Logic 0 displays peak value
/ Tare.................................................................................. Logic 0 offsets input value to zero
/ Tare Reset..........................................................................Logic 0 resets Tare value to zero
/ Meter Reset....................................................................... Logic 0 resets all meter functions
/ Function Reset ..........................................................Logic 0 resets peak values and alarms
/ Display Blank..............................................................................Logic 0 shuts off the display
/ Display Item............................................................................. Logic 0 displays Gross value

Power Requirements

Input Voltage rating (standard) .........85-264 Vac or 90-300 Vdc (DC range not UL approved)
Input Voltage rating (low voltage option) ............................................ 12-32 Vac or 10-48 Vdc
Power Line Frequency ................................................................................. DC and 47-63 Hz
Power Consumption, Max ........................................................................................... 5 Watts

Excitation Outputs

Voltage & Current Levels (jumper selectable) .................................. 5 Vdc ±5%, 100 mA max

.......................................................................................................

10 Vdc ±5%, 120 mA max

........................................................................................................

24 Vdc ± 5%, 40 mA max

Excitation Output Ripple .....................................................................................100 mVp max
Isolation from power and outputs ............................................................................... 250 Vac
Insulation dielectric strength to power and outputs..... 3.5 kV ac for 5 sec, 2.3 kV ac for 1 min
Isolation to signal common ........................................................................................... 50 Vdc

Advertising