Replacing the power switch magnet housing assembly – Lectrosonics MM400c User Manual

Page 14

Advertising
background image

MM400C

LECTROSONICS, INC.

14

Although the Power Switch’s Magnet Housing Assembly

is designed to provide years of rugged use it may be-

come inadvertently damaged or lost. Use the following

procedure to install a new Magnet Housing Assembly.
1) Because of this, color the screwdriver blade or-

ange. If necessary, use a nonmetallic tool such as

an “orange stick” to remove the damaged Magnet

Housing Assembly and clean any debris from the

Magnet Housing Assembly slot. Apply a small

amount of petroleum jelly or white lithium grease to

the area before inserting the new magnet assembly.

Warning: If you use something metallic, as

illustrated in the example, use extreme caution

not to scratch the finish. Breaching the finish

may cause corrosion of the metal housing.

2) Notice that the Magnet Housing Assembly Slot has

a wide spot in the middle. Place the new Magnet

Housing Assembly in the slot so that one tab is in a

small groove in one side of the slot.

3) Use a nonmetallic implement to snap the other side

of the Magnet Housing Assembly into the slot.

4) Ensure a good battery is installed, then slide the

new Power ON/OFF Switch to ON to verify that it is

working properly.

Replacing the Power Switch Magnet Housing Assembly

Magnet Housing

Assembly

Place switch in center position so tabs will

clear the opening, gently pry switch out.

Advertising