Controls and Functions

Preventing Internal Corrosion

It is very important that you properly dry the transmitter

when it becomes wet due to immersion or high levels of

perspiration

BEFORE opening any covers or connec-

tors.

Follow the procedure below for best results:

1. Carefully blot the transmitter dry with a clean paper

towel or cloth.

Remove all moisture.

After open-

ing any connector or cover, carefully blot up any

remaining moisture that may have remained around

the seal.

IMPORTANT! DO NOT CLOSE ANY COVER

OR CONNECTOR BEFORE MAKING CERTAIN

THERE IS NO MOISTURE IN OR NEAR THE

OPENING.

2. After use, it is important to store the transmitter

in a dry place with all access compartments and

connectors opened to allow any internal humidity to

evaporate. Specifically, open the Battery Compart-

ment, the Frequency Switch Cover Plate and fully

unscrew and remove the microphone connector

before storing.

Do not store wet and do not store

sealed.

If moisture is sealed inside the unit it has

nowhere to go other than to chemically react with

and destroy components and the printed circuit

board.

3. Lubricate all rubber O-rings with petroleum jelly

(such as Vaseline) after each use (included with

transmitter and O-ring replacement kits).

DO NOT

USE ANYTHING OTHER THAN PURE PETRO-

LEUM JELLY.

Silicone-based lubricants will dis-

solve the rubber. Failing to lubricate the O-rings

after each use will significantly shorten their life.

Power ON/OFF Switch

A waterproof, magnetic Power ON/OFF switch is

located on the unit’s side panel. The switch actually

consists of two components. A magnetically actuated

internal component and a magnet housing assembly.

The switch is designed so that the unit will still operate

if the Switch Magnet Housing Assembly is missing or

removed.
The function of the Power ON/OFF Switch can also be

changed so it operates as an audio mute switch. (See

Operating Instructions, Power Switch Function Selec-

tion.) These functions are illustrated in the chart below:

Power Switch Position

Function

ON

OFF

Normal, or

Applies Power

Turns Unit Off

Power Mode

to Unit

Audio Mute

Turns On Audio

Mutes Audio

Mode

If the MM400C Power ON/OFF Switch has been con-

figured for Audio Mute Mode, it is still possible to turn

off the transmitter without removing the battery. This

is done by placing the switch in the ON position, then

toggling the switch between the ON and OFF position

three times in less than five seconds, i.e., ON (Starting

Position)-OFF-ON-OFF-ON-OFF.
The user-selected configuration of the Power ON/OFF

switch is stored in memory and persists until reconfig-

ured by the user.

Power LED

The PWR LED provides an indication of the battery’s

condition. The PWR LED glows green when the battery

is good. The color changes to red when there is about

30 minutes of operation left with the recommended

lithium battery. (An alkaline battery will have about 20

minutes of life left.) When the LED begins to blink red,

there are only a few minutes of life left in the battery.

The PWR LED blinks red for a short period when the

transmitter is configured for Normal Mode and the

Power ON/OFF switch is set to OFF. At the end of the

power off sequence, then PWR LED extinguishes.

Note: A NiMH battery gives little or no warning

when it is depleted. If you use NiMH batteries in

the MM400C, we recommend trying fully charged

batteries first, noting the length of time that the

batteries will run the unit, then plan for somewhat

less time to determine when the battery needs to

be replaced. Some Lectrosonics receivers have

timers for use with these batteries.

A weak battery will sometimes cause the PWR LED to

glow green immediately after being put in the unit, but

will soon discharge to the point where the LED will blink

red or shut off completely.

Microphone Jack

Frequency Select

SwitchThumbscrew

and Cover Plate

Audio Level Control

Antenna

Battery

Compartment

Cap

Power ON/OFF Switch