ELECTRICAL FEATURES

Operator Control Station

NEMA 12 painted steel operator panel contains the
following:
- Allen Bradley push buttons for the following functions:

- Start

- Stop

- Jog

- Manual air blast

- Alarm, acknowledge, reset

- Emergency stop

- Speed pot

- Speed indicator

NEMA 12 machine mount painted steel electrical enclosure

including:
- Main disconnect switch
- Allen Bradley MicroLogix 1100 Modular hardware programmable logic controller with Ethernet
communication and online edition
- Allen Bradley PowerFlex AC inverter 3 HP with brake resistor
- Incremental encoder for scoop position

110V outlet and power for closer and labeler

Sensor for bag detection

Double loaf detector

Interlocks on all doors

SPECIFICATIONS

Throughput range:

35 - 60 loaves per minute

Electrical requirements:

Main Power - 6 KVA
Control Power - 24 VDC/120 VAC
Air Requirements - 6 SCFM @ 80 PSIG

Loaf size range:

Length: 8” (203 mm) - 16” (406 mm)
Width: 3-5/8” (92 mm) - 5-1/2” (140 mm)
Height: 3” (76 mm) - 6” (152 mm)

Approximate shipping weight:

2,500 lb. (1134 kg)

Approximate dimensions:

104” x 127” x 60”
(2642 mm x 3226 mm x 1524 mm)