Product calibration – Liquid Controls DMS Setup User Manual
Page 41

41
Product Calibration
Screen 10d: Product Calibration (4/6)
Gross Quantity is a read-only field. The gross quantity of
fluid measured by the meter during a product calibration
prover run is represented here. This is covered in detail
in the sections on Single-Point Calibration and Multi-Point
Calibration.
Gross Preset can be used to set a prover run volume.
This represents a volume of liquid to be run through the
meter during a proving run. This is covered in detail in
the sections on Single-Point and Multi-Point Calibration.
Temperature displays current temperature reading of the
probe. This field is not editable.
Net Quantity represents temperature compensated
quantity of current delivery. This field is not editable.
Press
Next (F1) to advance to Screen 10e on page 42.
(4/6) 1
Units: Gallons
48.8
0.0
80.5
47.1
PRODUCT CALIBRATION
Product #: 1
Gross Quantity:
Gross Preset:
Temperature:
Net Quantity:
Next Prev Cnfg Main