IT150N Remote Totalizer
pg
10
DOC# MN-150N-B
FUNCTION SELECTION
 
Reset Function 
 
Reset is incorporated to set the Display to 00000000. 
Reset is initiated externally by placing a magnet in the proximity of reset S7 located on the Display 
P.C.B. and indicated on the enclosure label as ‘RESET’. 
 
FIGURE 4
 
 
 
 
 
 
 
 
 
 
MISCELLANEOUS
 
Factored Digital Pulse Output 
 
This signal is an open drain configuration which can sink 1A continuously. The maximum drain voltage 
should not exceed 150VDC (V+). A pull-up resistor must be in series with V+ and TB1-3. The output is 
a 2ms negative pulse for each increment of the totalizer; i.e. 1 pulse for each count on the LCD. 
 
 
Typical Configuration-
 
 
 
 
 
 
 
Battery Replacement 
 
The battery is located on the Mounting P.C.B. and inserts into 2 sockets. When installing the battery, it is 
imperative to OBSERVE POLARITY. Simply pull the 3-board stack (See Figure #5) out of the enclosure, 
install the battery and reinsert the board stack. The display will be all zeros. 
 
 
 
 
 
 
 
 
 
 
IT150M
SIGNAL OUT +
SIGNAL OUT –
(V-)
V+
TB1-3
TB1-4
RL