Lightronics FXLE1232W User Manual

Page 3

Advertising
background image


Page

3

of

4

FXLE1232W LED FIXTURE

Version 0.1 OWNERS MANUAL 07/24/2013

www.lightronics.com

Lightronics

Inc.

509

Central

Drive

Virginia

Beach,

Va

234354

757

486

3588

Do not use chemicals or solvents when cleaning the
fixture. A mild detergent can be used sparingly if
needed. Ensure that the unit is dry before re-u

se.

REPAIR

The only FXLE1232W user serviceable part is a 5 mm
x 20 mm externally accessible fuse on the rear panel.


DISCONNECT THE POWER CORD BEFORE
CHECKING OR REPLACING THE FUSE.

Replace fuse ONLY with 3.15 Amp, 250VAC, fast
acting fuse.

Internal service on the unit by other than Lightronics
authorized agents will void the warranty.

If service is required, contact the dealer from whom
you purchased the item, or contact the Lightronics,
Service Department, 509 Central Drive, Virginia
Beach, VA 23454. Tel: 757 486 3588.

PHOTOMETRIC CHARACTERISTICS

ILLUMINATION (LUX)

BEAM DIAMETER (METERS)



















































Distance From Fixture

Beam Angle

10 feet

20 feet

30 feet

19 deg

--

2500

1214

26 deg

--

1723

628

36 deg

--

1200

516

50 deg

2160

635

--

Distance From Fixture

Beam Angle

10 feet

20 feet

30 feet

19 deg

--

7 ft

11 ft

26 deg

--

10 ft

16 ft

36 deg

--

14 ft

20 ft

50 deg

10 ft

16 ft

--

Advertising