Lightronics FXLE1260W User Manual

Page 2

Advertising
background image


Page

2

of

4

FXLE1260W LED FIXTURE

Version 0.1 OWNERS MANUAL 07/24/2013

www.lightronics.com

Lightronics

Inc.

509

Central

Drive

Virginia

Beach,

Va

234354

757

486

3588







DMX TERMINATION

A DMX chain should be terminated at the last
receiving device on the chain. This is done by
installing a commonly available 1/4 Watt, 120 Ohm
resistor across the DATA - and DATA + wires at the
last device. If you have only a few fixtures very close
together and a very short run to the controller then you
may be able to operate without the terminator.

OPERATION

A power ON/OFF switch is located at the rear of the
unit. A control panel on the back of the unit is used to
set the operating options. It consists of an LED display
and four buttons

(ESC, ENTER, DOWN, and UP)

.









Use

UP

and

DOWN

to scroll the available choices.

Push

ENTER

when you reach the option you want to

check or set. The current setting for the option will be
shown. Use

UP

and

DOWN

to change the setting.

Push

ENTER

to invoke the new setting. Use

ESC

to

exit from the sub menus.

DMX OPERATION

Use the

A - - -

menu to set the unit DMX starting

address. The range is

r001 - r511.

NOTE

The current version of the FXLE1260W will not
respond to DMX addresses above 255 even though
the addressing menu allows selections up to 511.


The fixture uses two DMX channels allocated as
follows:

CHANNEL 1:

Fixture Intensity (000 - 255)

CHANNEL 2:

Strobe Control (000 - 255)

000

is

Strobe

OFF


DEMO MODE (

dEnO)

The

DEMO

mode has 4 choices as follows:

SC00

External DMX control

SC01

Slow fade ON/OFF (stand alone operation)

SC02

Strobe effects (stand alone operation)

SC03

ON/OFF sequence (stand alone operation)

SC00 must be used when operating with an
external DMX controller.

If the unit was switched to another

DEMO

mode then it

must be returned to

SC00

and then a RESET (rESt)

must be done.

NAST MODE

This function is not currently supported.

RESET (

rESt)

The reset function enables DMX operation after stand
alone operation.

Push

ENTER

when

rESt

is shown. The display will

show

OFF

. Push UP to execute the reset. The display

will revert to show the DMX starting address.

MAINTENANCE AND REPAIR







TROUBLESHOOTING

Check that you have power applied to the unit.
Check the DMX control cable.
Check the address settings of the unit and controller.

CLEANING

DISCONNECT THE POWER CORD BEFORE
HANDLING THE UNIT.


PIN #

SIGNAL NAME

1 DMX

COMMON

2

DMX DATA -

3

DMX DATA +

4 NOT

USED

5 NOT

USED

ESC

UP

DOWN

ENTER

CONTROL PANEL

DANGER DO NOT OPEN UNIT

RISK OF ELECTRIC SHOCK

RISK OF FIRE

Advertising