Magnum Venus Plastech APS E-FIT-F-CMB-APS-6 User Manual
Page 15
MAINTENANCE INSTRUCTIONS FOR
FLAT SPRAY TUNGSTEN CARBIDE TIPS
Your carbide tip has a precisely machined orifice and with proper care will give a long useful life. Remem-
ber, the orifice tip is brittle . . . it should never be dropped . . . or probed with a sharp metal object. The
following steps should be taken to keep the tip clean and ready for use:
STEP 1
STEP 2
STEP 3
STEP 4
Immediately after spraying
submerge spray tip in
solvent until film or coating
dissolves completely.
Blow out tip with
compressed air.
Use pointed wooden stick
to remove any particles that
are left.
Inspect carefully through
magnifying glass or
microscope. Repeat steps
1-3 if necessary.
NOTE: All tips have been paint-spray tested. Some orifices are extremely small and barely
visible. Check with Step 4.