Introduction, Mkvi output information, Manuals goal – Magnum Venus Plastech Flex Molding Process MKVI Mix User Manual
Page 15: 100cc

MKVI Mix Meter System Operations Manual
Rev. 08/2013
Page | 15
Introduction:
MANUALS GOAL:
To create a better knowledge and understanding of the operation, maintenance, and
repair of MAGNUM VENUS PLASTECH (M.V.P.) equipment. To assist the equipment
operator in all aspects of the equipment operation and maintenance thus allowing for
higher production and better quality.
This manual covers the MKVI Mix Meter base unit and some optional items that may not
be included on your machine. It is important to familiarize yourself with your unit to be
able to properly operate and maintain it.
When performing repair layout parts on a clean towel or surface in the order they were
removed to make it easier to reassemble. Properly clean all parts and replace any
damaged items as necessary. It is important to have a current drawing of the part being
repaired to assist in assembly.
For more detailed component repair please refer to the following sections:
100CC Fluid Section (Fixed Fluid Section)
Megaject Auto Head
SP4 Flush Tank Assembly
Alternative Fluid Section (Catalyst / Hardener)
Catalyst Pump (0.5% - 3.5%) (188:1
– 26:1)
20cc Fluid Section (3.5% - 20%) (34:1
– 5:1)
50cc Fluid Section (10% - 50%) (14:1
– 2:1)
100cc Fluid Section (20% - 100%) (7:1- 1:1)
Optional CFH-5000 Inline Resin Heater (see CFH-4000 Resin Heater Manual)
MKVI Output Information
Fluid
Section
Cat Pump
20cc Pump
50cc Pump
100cc Pump
Low
High
Low
High
Low
High
Low
High
100cc
Liters/min. 8.002 8.29
8.05
9.60
8.29 12.00 9.12 16.00
Ratio
188:1 26:1
34:1
5:1
14:1
2:1
7:1
1:1
The above outputs are based on 40 cycles a minute. They are theoretical outputs; actual output will be
slightly lower and will depend on several factors.