Magnum Venus Plastech INNOVATOR MEGAJECT 5000 (8001) User Manual
Page 28
Advertising

MAGNUM VENUS PLASTECH
Innovator Megaject Manual
28
RGA adjustment
The time between strokes permitted to pass before the RGA alarms and the
volume of the alarm whistle can be adjusted by the user.
The pneumatic RGA is located in the lid of the control box, behind the
predetermining counter. The mechanical timer is shown in figure 5.3. Turn the
knob to adjust the timer to the required time, between 20 – 300 seconds. The dial
shows seconds divided by 10, therefore to set the timer to 100 seconds, adjust
the dial to 10.
Figure 5.3 – RGA mechanical timer
The RGA alarm whistle volume can be changed by adjusting the flow controller
that is in line with the whistle.