VHPC-2200 Metering Pump Manual

Rev. 05/2012

Page | 19

9.

Carefully put the inlet Ball (VHPC-2223) into the bottom of the Inlet body (VHPC-
2215-B).

10. Install the Ball stop (VHPC-2220) into the Inlet body

(VHPC-2215-B) over the ball. The Ball stop will fit over
the ball with the ball being trapped in the bottom of the
inlet body.

11. Install a new O-ring (O-E-025) onto the bottom end of the

(short thread end) of the Cylinder (VPHC-2216) and
thread it into the Inlet body (VHPC-2215-B), using a 1-3/8”
wrench secure in place.

12. Place a new O-ring (O-E-025) onto the top of the

Cylinder (VPHC-2216). Thread the Lock nut (VHPC-
2221) all the way down on the cylinder.

13. Take the assembled Outlet body and pull the piston rod

all the way to the top of the stroke. Screw the
assembled Outlet body onto Cylinder (VHPC-2216) until
it bottoms out. If the inlet and outlet hose fittings are not
in proper position to attach to pump drive, unscrew the
outlet body slightly before bring the Lock nut (VHPC-
2221) up and tightening it against the outlet body. If not
sure, complete assembly and attach to drive before
tightening the lock nut.

14. Install the pump back onto the drive. Orient the Outlet

body (VHPC-2217) so hoses do not interfere with the drive. Bring the Lock nut
(VHPC-2221) up against the Inlet body (VHPC-2215-B) and tighten.

15. Attach all fluid hoses.













Cylinder

O-ring

O-ring

Ball Cage

Inlet Ball

Inlet Body

Inlet Fitting

O-ring