Magnum Venus Plastech CB-6000-RT - Resin Monitor User Manual
Page 24

CB-6000-RT Material Monitor Manual
Rev. 10/2012
Page | 24
Resin Display Value = 60 for minutes multiplied by the decimal place x10 = 0.0
Minutes =
60
Decimal place:
x 10
Display Value (rdSP 1) 600 (pounds or kilogram per minute)
Resin Rate Input value:
Pounds
Kilogram
Pulses per pound
14
31
Decimal display
x 10
x 10
Input Value (r I
n
P 1) =
140
310
This number may need to be adjusted for the resin viscosity and specific gravity but it is
a starting point. Make note of all materials used (resin data sheet), pump settings,
nozzle size and nozzle type this will help to duplicate this setup in the future.
QUICK REFERENCE:
Use the to select the numeric column and the and to change its value.
Enter the desired Set Point number then press through the remaining parameters
unit the display reads
.
Note: Pressing the will exit the programming process without saving.
PAR
END
Pro
F1
4 - rtE
rdSP 1
PAR
RST
F1
F2
PAR
DSP
Push 3 times
600.0
RST
r I
n
P 1
PAR
580.0
RST