Basic Troubleshooting.
Symptom
Cause
No power when power switch is turned on.
Check fuse inside panel
No totals on display
Verify proper scale factor
Verify ensor light is going on and off with magnet
reads
Check for broken sensor cable
Remote reset will not work
Check for broken sensor cable
Displays read different upon calibration
Verify the same scale factor is in each display
Scale factor has to be adjusted way out of
range from initial entry or constantly
adjusted
Double counts from magnet. Inspect proximity switch
LED to ensure that only 1 count per magnet is being
detected.
Inspect mag rod to ensure that all magnets are in
place.
Head of switch should be approximately 4mm from
magnet. Adjust as necessary.
Inspect pumps for wear or feed issues
Test shots not matching counter
Adjust scale factor
Inspect pumps for wear or feed issues.