Machine Guards
1. Main Pump Guards. The moving mechanical parts of the machine are guarded
to prevent any injury from moving machine parts during the operation of the
machine. GUARDS MUST BE IN POSITION DURING MACHINE OPERATION. The
end guard may be opened for ratio adjustment using a suitable allen key.
Catalyst System (Polyester option only)
1. Catalyst Pump. Operated by the main resin pump. Catalyst ratio is indicated on
the ratio arms.
2. Catalyst Overpressure Valve. If during the operation of the machine, the
catalyst system becomes blocked for any reason causing the catalyst to exceed a
pre-set pressure, the catalyst overpressure valve will activate and stop the
machine. Refer to Megaject Doctor for fault finding.
3. Catalyst Container. Catalyst store with feed and return pipes attached.