Talon Internal Mix Gun Manual

Rev. 10/2013

Page | 32

Flush Problems - continued

Problem

Possible Cause(s)

Recommended

Solution(s)

Solvent leaking from the front of
the gun block or mix chamber

Seal Body O-ring damaged

Replace the Seal Body O-ring

Dirty or Damaged Flush Valve
Body

Clean or Replace the Flush
Valve Body as needed

Solvent Pressure too high

Reduce solvent tank pressure

Flush Seal Body loose or off
Button

Connect and tighten the Flush
Seal Body onto the Button

Resin leaking into the solvent
supply tube / flush tank

Damaged Flush Seal O-ring

Replace the O-ring on the Flush
Seal

Flush Seal Body loose or off
Button

Connect and tighten the Flush
Seal Body onto the Button


General Problems

Problem

Possible Cause(s)

Recommended

Solution(s)

Air leaking around the Air Valve

Damaged O-ring on the valve

Check and replace O-ring on the
Air Valve.
Check inside the handle for
scratches or damage

Air constantly leaking around 3-
Way valve Shaft

Faulty 3-Way Valve

Replace the 3-Way valve

Air constantly leaking from
exhaust port

Faulty 3-Way Valve

Replace the 3-Way valve

Material leaking around the Mix
Chamber

Loose Mix Housing

Tighten the cap screws holding
the mix housing in place

Damaged Mix Housing Seal or
gun block

Replace the mix housing Seal
Check Gun Block for scratches
or damage