Factory data screen, Compensation options, Restore factory – Max Machinery 290 Trasmitter Interface User Manual
Page 8: Disable, Perform field
 
an ISO 9001:2008 certified company
8
IH 290-100-350 • rev. 2/2012 • ©2012 Max Machinery, Inc.
Factory Data Screen
The Factory Data tab shows calibration 
settings that generally will only need 
to be set at the factory. Most fields are 
password protected. If needed, contact 
the factory for details.
Compensation Options
Compensation is a software feature 
where the transmitter measures the 
rotational speed of the meter thru one 
complete revolution, and then corrects 
for this variation. Because different 
mechanical meters contain design 
differences resulting in cyclic speed 
variation, this process is able to smooth 
out this cyclic error without adding any 
signal filtering. Note that it is critical 
that a constant flow is passing thru the 
meter when this compensation is done 
so that only mechanical variation is 
mapped by the transmitter. 
Restore Factory
This option restores the compensation 
table to the values that were originally 
learned at the factory. Generally used 
after a field compensation yields 
poor results.
Disable
This turns off the cyclic compensation and is only recommended for a field replacement transmitter when a steady flow 
is not available to perform a FIELD COMPENSATION. 
Perform Field
This option characterizes the flow meter and sensors at a steady flow rate to provide optimal spacing of the output 
pulses. Use when optimal output response is needed, Factory Compensation is not available or the application is very 
low flow or high viscosity fluid.
NOTE: You must have a steady flow during compensation.