Electrical Data
UPS Power (kVA)
65
80
100
125
160
200
250
Standards
●
Underwriters Laboratories, Listed to
UL1778 (Designed to 60950);
c-UL to CSA C22.2
●
CE
●
NEMA PE-1
●
ASME
●
ASA-C-39.1-1984
●
FCC PT 15, Subpart J, Class B
●
National Electrical Code
●
OSHA
●
IEEE 587 ANSI C 62.41-1980
●
ISO 9001
●
IBC (International Building Code)
Ratings A-F, Site Specifi c
FirstLine P 80, 100, 125kVA Part Numbers
Model
kVA / kW
Voltage
FLU-65-00
65VA/58.5kW
480V - 480Y/277
FLU-80-00
80kVA/72kW
480V - 480Y/277
FLU-100-00
100kVA/90kW
480V - 480Y/277
FLU-125-00
125kVA/112.5kW
480V - 480Y/277
FLU-160-00
160kVA/144kW
480V - 480Y/277
FLU-200-00
200kVA/180kW
480V - 480Y/277
FLU-250-00
250kVA/225kW
480V - 480Y/277
BY-PASS
Nominal voltage
480Vac 3-phase (with or without neutral)
Nominal voltage tolerance
± 15% (can be regulated from ± 10% to ± 25%
from the control panel)
±20% (can be regulated from ±5% to ±25%
from the control panel)
Nominal frequency
60 Hz
Frequency tolerance
± 2% (can be regulated up to ± 6% from the control panel)
Switching time inverter-by-pass with Inverter
synchronized (UPS Normal)
Approx. 0ms
Switching time inverter-by-pass with
non-synchronized Inverter (UPS in “Normal Mode”)
20ms
(Can be calibrated from 10 to 100 ms or with inhibition of
transfer onto bypass)
Switching time from by-pass to Inverter
(Stand-by / On Mode)
from 2 to 5ms
Delay in transferring to Inverter after the switching
onto by-pass
4 sec
Overload Capacity of by-pass line (kVA)
125 % for 60 minutes, 150 % for 10 minutes
110% for 60 min., 125% for 10 min.
Short circuit capacity of by-pass line (x nominal
current)
1 second
500 ms
200 ms
100ms
10ms
65
20
23
26
30
40
80
15
18
21
22
30
100
12
15
17
18
25
125
10
12
14
15
20
160
9
10
11
12
18
200
7
8
9
10
14
250
9
10
11
12
18
SYSTEM
On-Line AC/AC effi ciency
• Full load
• Load 50%
93 %
93.5 %
93.5%
94%
94%
94.5%
Effi ciency with UPS in STAND-BY mode
98 %
Full Load Heat Rejection BTU/hr
15,033
18,500
23,120
28,900
36,880
46,230
57,780
Maximum current dispersion
300mA maximum
MECHANICAL
Dimensions – inches
UPS Power (kVA)
65
80
100
125
160
200
250
Height x Width x Depth – inches (mm)
75 (1900) x 31.5 (800) x 33.5 (850)
75 (1900) x 39 (1000) x 33.5 (822)
Weight – lbs. / Kg
1,213 / 550
1,213 / 550
1,433 / 650
1,544 / 700
1984 / 900
2,205 / 1000
2,425 / 1100
Freestanding NEMA 1 enclosure, powder coat painted black color with textured fi nish, bottom access for conduit entries
ENVIRONMENTAL
Ambient temperature
0° C to 40° C
Storage temperature
-25° C to 70° C
Relative humidity
20 – 90% non-condensing
Altitude
3,281 feet without derating
Audible noise
65 dBA @ 1 meter
68 dBA @ 1 meter