Electrical Data

UPS Power (kVA)

65

80

100

125

160

200

250

Standards

Underwriters Laboratories, Listed to

UL1778 (Designed to 60950);
c-UL to CSA C22.2

CE

NEMA PE-1

ASME

ASA-C-39.1-1984

FCC PT 15, Subpart J, Class B

National Electrical Code

OSHA

IEEE 587 ANSI C 62.41-1980

ISO 9001

IBC (International Building Code)

Ratings A-F, Site Specifi c

FirstLine P 80, 100, 125kVA Part Numbers

Model

kVA / kW

Voltage

FLU-65-00

65VA/58.5kW

480V - 480Y/277

FLU-80-00

80kVA/72kW

480V - 480Y/277

FLU-100-00

100kVA/90kW

480V - 480Y/277

FLU-125-00

125kVA/112.5kW

480V - 480Y/277

FLU-160-00

160kVA/144kW

480V - 480Y/277

FLU-200-00

200kVA/180kW

480V - 480Y/277

FLU-250-00

250kVA/225kW

480V - 480Y/277

BY-PASS
Nominal voltage

480Vac 3-phase (with or without neutral)

Nominal voltage tolerance

± 15% (can be regulated from ± 10% to ± 25%

from the control panel)

±20% (can be regulated from ±5% to ±25%

from the control panel)

Nominal frequency

60 Hz

Frequency tolerance

± 2% (can be regulated up to ± 6% from the control panel)

Switching time inverter-by-pass with Inverter
synchronized (UPS Normal)

Approx. 0ms

Switching time inverter-by-pass with
non-synchronized Inverter (UPS in “Normal Mode”)

20ms

(Can be calibrated from 10 to 100 ms or with inhibition of

transfer onto bypass)

Switching time from by-pass to Inverter
(Stand-by / On Mode)

from 2 to 5ms

Delay in transferring to Inverter after the switching
onto by-pass

4 sec

Overload Capacity of by-pass line (kVA)

125 % for 60 minutes, 150 % for 10 minutes

110% for 60 min., 125% for 10 min.

Short circuit capacity of by-pass line (x nominal
current)

1 second

500 ms
200 ms

100ms

10ms

65

20
23
26
30
40

80

15
18
21
22
30

100

12
15
17
18
25

125

10
12
14
15
20

160

9
10
11
12
18

200

7
8
9

10
14

250

9

10
11
12
18

SYSTEM
On-Line AC/AC effi ciency

• Full load
• Load 50%

93 %

93.5 %

93.5%

94%

94%

94.5%

Effi ciency with UPS in STAND-BY mode

98 %

Full Load Heat Rejection BTU/hr

15,033

18,500

23,120

28,900

36,880

46,230

57,780

Maximum current dispersion

300mA maximum

MECHANICAL

Dimensions – inches

UPS Power (kVA)

65

80

100

125

160

200

250

Height x Width x Depth – inches (mm)

75 (1900) x 31.5 (800) x 33.5 (850)

75 (1900) x 39 (1000) x 33.5 (822)

Weight – lbs. / Kg

1,213 / 550

1,213 / 550

1,433 / 650

1,544 / 700

1984 / 900

2,205 / 1000

2,425 / 1100

Freestanding NEMA 1 enclosure, powder coat painted black color with textured fi nish, bottom access for conduit entries

ENVIRONMENTAL
Ambient temperature

0° C to 40° C

Storage temperature

-25° C to 70° C

Relative humidity

20 – 90% non-condensing

Altitude

3,281 feet without derating

Audible noise

65 dBA @ 1 meter

68 dBA @ 1 meter