Minuteman H20 Walk-Behind Scrubber Disc Traction Drive User Manual

Page 34

Advertising
background image

34

Troubleshooting

Problem Possible

Cause Remedy


Poor water pick-up

Worn or torn squeegee blades

Rotate or replace blades

Recovery tank full

Empty recovery tank

Recovery tank drain hose leak

Secure drain hose cap, replace o-ring
in cap if damaged

Recovery tank lid gasket leak

Replace gasket lid cover properly

Debris caught in squeegee

Clean squeegee

Vacuum hose clogged Remove

debris

and

flush

hose

Using too much solution

Adjust solution control valves

Recovery hose to squeegee or tank
disconnected or damaged

Reconnect or replace recovery hose


Poor scrubbing performance

Worn brush

Replace brush

Wrong brush or cleaning chemical

Consult Minuteman

Debris caught on scrub brushes

Remove debris

Moving machine too fast

Slow down

Not using enough solution

Adjust solution flow setting

Low battery charge

Recharge batteries

Inadequate solution flow or
no solution to the floor

Solution tank empty Fill

solution

tank

Solution lines, valve, filter clogged

Flush lines, and clean solution filter.

Solution Lever in down position

Move lever up

Machine does not move

Directional switch in neutral position

Activate switch in FWD or REV
position

Squeegee is down and directional
switch is in reverse position

Raise squeegee when in reverse
mode

Traction drive circuit breaker has tripped

Reset circuit breaker

Batteries lost power

Recharge batteries

Advertising