Storing machine troubleshooting – Minuteman TRS 14 Total Recovery System User Manual

Page 11

Advertising
background image

Parts and Instruction Manual

Page 8

Storing Machine

Troubleshooting

1. Before storing machine, be certain to completely drain
and
rinse tanks of all water and solution.
2. Drain and dry the vacuum hose as well, using the drain
hose provided
3. Store machine in a dry area in the upright position.
4. Open recovery tank cover to promote air circulation

SYMPTOM:

UNIT WILL NOT TURN ON:

PROBLEM:

Not plugged in.

SOLUTION:

Plug machine in proper outlet.

PROBLEM:

Circuit breaker has popped.

SOLUTION:

Reset circuit breaker. Make sure no other items are running on the same circuit as
machine. Outlet must be a 15-amp circuit.

PROBLEM:

Wire from power cord has become disconnected from terminal block.

SOLUTION:

Reattach wire to terminal block.

SYMPTOM:

PUMP IS NOT RUNNING PROPERLY:

PROBLEM:

Quick disconnects are not completely locked together.

SOLUTION:

Snap quick disconnects firmly together.

PROBLEM:

The solution tank is empty.

SOLUTION:

Fill the solution tank up with a premixed detergent.

PROBLEM:

Jet on tool is clogged.

SOLUTION:

Clean jet with soft wire brush or remove jet and flush clean.

PROBLEM:

Filters are clogged.

SOLUTION:

Remove filters and rinse clean with water.

PROBLEM:

Brass check valve is stuck.

SOLUTION:

Replace with new check valve.

PROBLEM:

Pump wire has become disconnected.

SOLUTION:

Reconnect wire.

PROBLEM:

Switch on switch plate is bad.

SOLUTION:

Replace switch.

PROBLEM:

Pump motor brushes are worn out.

SOLUTION:

Replace pump.