Parts and Instruction Manual

Page 6

Machine Set Up

Pre-Operation

1. Vacuum and remove all debris.
2. Perform MACHINE SETUP procedures.
3. Inspect power cord for damage.

1. Carefully check carton for signs of damage.
Report damage at once to freight carrier.
The machine is shipped fully assembled
and is ready for use.
2. Open lid of solution tank. Fill solution tank
with water or approved cleaning agent.

WARNING: Flammable materials can
cause an explosion or fire. Do not use flammable
solutions or materials in tank(s).

FOR SAFETY: When using machine, follow
mixing and handling instructions on chemical
containers.

ATTENTION: If using powdered cleaning
chemicals, mix prior to adding.

3. Attach solution hose. (Located front of
machine.)

NOTE: Make sure the quick
disconnects snap together firmly. As
you do this, always inspect hoses for
cracks or fraying. Do not use if hoses
are damaged.

4. Attach other end of solution hose to wand.

5. Attach vacuum hose to recovery tank.

6. Locate a 20 Amp dedicated power circuit, and
plug the machine

cord in. The outlets must

be properly grounded. Plugging into an
ungrounded or improper outlet can result in
equipment damage,

fire, and/or harm to the

operator. NEVER DISABLE THE
GROUND PIN, AS SERIOUS PROBLEMS CAN
RESULT!

FOR SAFETY: Do not operate machine unless
cord is properly grounded.

FOR SAFETY: Do not operate machine with
the use of an extension cord.

Set Up

1. Turn pump switch to “Hi Pressure” setting.

2. Step lightly on Power Prime for 30 seconds to prime
pump completely. Use regulator adjustment to set pump
at desired pressure on gauge.

3. Hook up your auto fill and pump out hoses to the
appropriate connections on the back of the machine.

4. Switch on Pump-Out pump. NOTE: Pump will not begin
to operate until tank is partially filled. The pump out is
controlled by a sensor in the tank. MAKE SURE YOUR
PUMP OUT HOSE IS SECURED TO A DRAIN.

5. Attach Auto Fill hose to a water inlet, such as a sink or a
garden hose. Turn on the water at medium to medium
low pressure. Monitor solution tank as it fills for the first
time, to ensure that the Auto Fill shuts off correctly.

6. Switch on both Vacuum 1 and Vacuum 2

7. Begin cleaning. As you clean, monitor your tank levels.
The clean water tank should never be run empty, and the
dirty water tank should never be run full.

Operation

Priming

To prime the TRS simply connect all the solution hoses
i.e. chemical metering, spray gun. Then turn on the pump
switch and push down on the priming lever. At this point
the TRS will reach its operating pressure.