KNK/KNU 50

Neutron Flux Instrumentation

KNK/KNU 50

Neutron Ionization Chambers

The KNK/KNU 50 neutron ionization chambers are

designed for neutron fl ux monitoring in ex-core

positions. The neutron sensitivity of these ionization

chambers is achieved by the coating of one electrode

with enriched boron-10. Thermal neutrons react with

the isotope boron-10 emitting alpha particles, which

produces ionization in the gas within the detector.

Their discharge on the electrodes causes charge pul-

ses. These charge pulses are integrated to a DC cur-

rent, which can be measured in the external circuit.

APPLICATIONS

• Operational process monitoring

○

Measurement of the neutron fl ux densitiy outside

the reactor core for power reactors and research

reactors in the intermediate range (KNK 50) and

power range (KNU 50)

RELATED PRODUCTS

• Proportional counters BF3 fi lled

• Self-powered neutron detectors

• Digital signal processing channels for start-up and

power range

FEATURES

●

Wide measuring range

●

Simple and rugged construction

●

Saturation proof

●

Large and steady sensitive length

●

Output signal: DC current starting at 1 pA

●

Compensation of gamma radiation (KNK 50)

●

LOCA proof (KNK 50 SAC)