Detectors and input signals, No external preamplifi ers, Neutron fl ux deviation between top and bottom – Mirion Technologies DGK 250 User Manual

Page 2: Mechanical vibrations: < 5 g, 5 hz

Advertising
background image

Since norms, specifi cations and designs are subject to occasional change, please ask for confi rmation of the information given in this publication.

Mirion Technologies (MGPI) SA

Route d’Eyguières

FR-13113 Lamanon

France

T +33 (0) 4 90 59 59 59

F +33 (0) 4 90 59 55 18

Mirion Technologies (MGPI) Inc

5000 Highlands Parkway

Suite 150

Smyrna, GA 30082

USA

T +1 770 432 2744

F +1 770 432 9179

Mirion Technologies (MGPI H&B) GmbH

Landsberger Strasse 328a

DE-80687 Munich

Germany

T +49 (0) 89515 13-0

F +49 (0) 89515 13 169

Mirion Commercial (Beijing) Co., Ltd.

Shanghai Jiangchang Commercial Branch

Room 801, 78 Jiangchang SanLu

Zhabei District, Shanghai 200436

PR of China

T +86 21 6180 6920

F +86 21 6180 6924

DGK 250

Neutron Flux Instrumentation

www.mirion.com

144967EN-C

DETECTORS AND INPUT SIGNALS

●

Boron coated ionization chambers (compensated or
non-compensated) e.g. KNU 50 or KNK 50

●

No external preamplifi ers

●

Cable to the DGK 250: coaxial cable, no limitation of
length

●

Detector supply 0 ... 1 kV located in the central
electronic unit

●

Selectable ranges of input signals 0 ... 10/20/50 μA

DIGITAL SIGNAL PROCESSING

●

80C31/32 multi-processor system

●

Program memory: EPROM

●

Parameter memory: CMOS-RAM with integrated
Li-battery

●

Data interface: RS232 and/or RS485

●

Internal LC-display: 2 x 16 characters

OUTPUT SIGNALS

●

Neutron fl ux at top and bottom position, individually
calibrated

●

Average neutron fl ux, calibrated to reactor power,
e.g. 0 ... 125 %Pn

●

Neutron fl ux deviation between top and bottom

●

Analog outputs: 0/4 ... 20mA/600 Ω, insulated

●

Binary outputs: insulated relais change overs,
60V/0.5A or 125V/1A

OTHER CHARACTERISTICS

●

DC power supply: 18 ... 33 VDC, approx. 1.6A at 24 V

●

Optional: AC power supply: 230 VAC or 115 VAC
+10%/-15%, approx. 40 VA

●

Operating temperature: 0 ... 70°C (32 ... 158°F)
for the main electronics

●

Mechanical vibrations: < 5 g, 5 ... 100 Hz

●

19” modular system according to IEC 60297

●

Rack size (W×H×D): 483 mm × 133 mm × 280 mm
(19 in x 5.2 in x 11 in)

●

Plug-in boards: 100 mm × 160 mm (3.9 in x 6.3 in)