Detectors and preamplifiers, Pulse detectors for dak 250-i, Bf3- or he3-counter tubes – Mirion Technologies DAK 250 User Manual

Page 2: B10-proportional counters, Fission chambers in pulse mode, Pulse preamplifi er nv 320, Remote pulse generator for testing, Mechanical vibrations: < 5 g, 5 hz

Advertising
background image

Since norms, specifi cations and designs are subject to occasional change, please ask for confi rmation of the information given in this publication.

Mirion Technologies (MGPI) SA

Route d’Eyguières

FR-13113 Lamanon

France

T +33 (0) 4 90 59 59 59

F +33 (0) 4 90 59 55 18

Mirion Technologies (MGPI) Inc

5000 Highlands Parkway

Suite 150

Smyrna, GA 30082

USA

T +1 770 432 2744

F +1 770 432 9179

Mirion Technologies (MGPI H&B) GmbH

Landsberger Strasse 328a

DE-80687 Munich

Germany

T +49 (0) 89515 13-0

F +49 (0) 89515 13 169

Mirion Commercial (Beijing) Co., Ltd.

Shanghai Jiangchang Commercial Branch

Room 801, 78 Jiangchang SanLu

Zhabei District, Shanghai 200436

PR of China

T +86 21 6180 6920

F +86 21 6180 6924

DAK 250

Neutron Flux Instrumentation

www.mirion.com

144966EN-C

DETECTORS AND PREAMPLIFIERS

●

Pulse detectors for DAK 250-i:

○

BF3- or He3-counter tubes

○

B10-proportional counters

○

Fission chambers in pulse mode

●

Pulse preamplifi er NV 320:

○

Input and output impedance matched to the
impedance of the cables

○

Remote pulse generator for testing

●

Ionisation chambers for DAK 250-g: compensated or
non-compensated

●

Current-to-frequency-converter NV 102H: 10 decades
of measuring range

●

Detector supply 0 ... 0.5/1/2/4 kV located in the
central electronic unit

DIGITAL SIGNAL PROCESSING

●

80C31/32 multi-processor system

●

Program memory: EPROM

●

Parameter memory: CMOS-RAM with integrated
Li-battery

●

Data interface: RS 232 and/or RS 485

●

Internal LC-display: 2 x 16 characters

OUTPUT SIGNALS

●

Linear and/or logarithmic count rate or neutron fl ux

●

Neutron fl ux change rate = 1 / reactor period to be
confi gured, e.g. -1.25 ... 0 ... 12.5 %/s corresponding
to -80 ... ∞ ... +8 s reactor period

●

Analog outputs: 0/4 ... 20mA/600 Ω, insulated

●

Binary outputs: insulated relay change overs,
60V/0.5A or 125V/1A

●

Optional: reactimeter on a single additional interface
board NK 21

OTHER CHARACTERISTICS

●

DC power supply: 18 ... 33 VDC, approx. 1.6A at 24 V

●

Optional: AC power supply: 230 VAC or 115 VAC
+10%/-15%, approx. 40 VA

●

Operating temperature: 0 ... 70°C (32 ... 158°F)
for the main electronics

●

Mechanical vibrations: < 5 g, 5 ... 100 Hz

●

19” modular system according to IEC 60297

●

Rack size (W×H×D): 483 mm × 133 mm × 280 mm
(19 in x 5.2 in x 11 in)

●

Plug-in boards: 100 mm × 160 mm (3.9 in x 6.3 in)

DAK 250
Schematic diagram

Advertising