Physical characteristics, Radiation detected: gamma, Energy range: 80 kev to 7 mev – Mirion Technologies GIM 203K User Manual

Page 2: Typical measurement range: 10, Sv/h (10, Rem/h) environmental characteristics, Periodic temperature (detector), Rad), Detector: 2 10, Gy (2 10

Advertising
background image

Since norms, specifi cations and designs are subject to occasional change, please ask for confi rmation of the information given in this publication.

Mirion Technologies (MGPI) SA

Route d’Eyguières

FR-13113 Lamanon

France

T +33 (0) 4 90 59 59 59

F +33 (0) 4 90 59 55 18

Mirion Technologies (MGPI) Inc

5000 Highlands Parkway

Suite 150

Smyrna, GA 30082

USA

T +1 770 432 2744

F +1 770 432 9179

Mirion Technologies (MGPI H&B) GmbH

Landsberger Strasse 328a

DE-80687 Munich

Germany

T +49 (0) 89515 13-0

F +49 (0) 89515 13 169

Mirion Commercial (Beijing) Co., Ltd.

Shanghai Jiangchang Commercial Branch

Room 801, 78 Jiangchang SanLu

Zhabei District, Shanghai 200436

PR of China

T +86 21 6180 6920

F +86 21 6180 6924

GIM 203K

Gamma & Neutronic Monitors

PHYSICAL CHARACTERISTICS

●

Radiation detected: gamma

●

Detector: stainless steel ionization chamber
(KG 221 SER)

●

Energy range: 80 keV to 7 MeV

●

Typical measurement range: 10

-6

to 10

+3

Sv/h

(10

-4

to 10

+5

rem/h)

ENVIRONMENTAL CHARACTERISTICS

●

Long term temperature: +10°C to +40°C

(+50°F to +104°F)

●

Periodic temperature (processing unit): -5°C to +55°C
(+23°F to +131°F)

●

Periodic temperature (detector):

○

+165°C (329°F) during 12 hours

○

+225°C (437°F) for accident conditions

●

MTBF: > 20 000 hours

●

TID:

○

Processing unit: 25 Gy (2.5 10

+3

rad)

○

Detector: 2 10

+6

Gy (2 10

+8

rad)

●

Protection index:

○

Processing unit: IP65 and IK07

○

Detector: IP67 and IK07

MECHANICAL CHARACTERISTICS

●

Dimensions:

○

Processing unit:
390 mm x 196 mm x 187 mm (15.3 in x 7.7 in x 7.3 in)

○

Detector: 240 mm (9.5 in) x Ø 280 mm (11 in)

●

Weight:

○

Processing unit: 8.5 kg (18.7 lb)

○

Detector: 24 kg (53 lb)

●

Color: gray RAL 7030 (decontaminable paint)

ELECTRICAL CHARACTERISTICS

●

Power supply: 230 Vac – 50 Hz or 120 Vac – 60 Hz

●

Data link outputs: 1 RS232 and 2 isolated RS485

●

Alarm relays: 3 SPDT relays

●

I/O: 2 isolated analog outputs and 1 isolated analog
input (0/4-20 mA)

SIGNALING (Applicable to LPDU only)

●

Alphanumeric display: measurement, status…

●

Sound alarm: buzzer 90 dBA at 1 meter

●

Visual alarm: 3 lights (red, yellow, green)

REFERENCE STANDARDS

●

Nuclear: IEC60951 and IEC60532

●

Environmental: IEEE323 and IEC60780, including
LOCA test, RG 1.97

●

Seismic: IEEE344 and IEC60980

●

EMC: 2006/95/CE and 2004/108/CE, EPRI 102323,
MIL STD 461 E, IEC61000-6-2 and IEC61000-6-4

VERSIONS

●

230 Vac or 120 Vac

●

LPDU or LPU

●

With or without RS485 junction box

●

Mineral or organic detector cable

●

Detector cable length: from 10 m (32.8 ft)
to 70 m (229.6 ft); length up to 140 m (459.3 ft) is also
possible, by means of two sets of mineral extension
cables

●

Junction box cable length: 2 m (5.65 ft), 5 m (16.4 ft)
or 10 m (32.8 ft)

ACCESSORIES

●

Calibration tools

●

Software

●

USB converters

●

Seismic qualifi ed wall mounting bracket

www.mirion.com

144303EN-F

Advertising