Carclean system, Troubleshooting guide cont, Maintenance – MotorVac CarClean System User Manual

Page 7: What it means corrective action

Advertising
background image

Troubleshooting Guide Cont.

During normal operation: Immediately after the power supply is connected, the
machine will illuminate all 3 LED’s momentarily (internal sef-test). No lights should
be on after the self-test completes. Once the ‘start’ button is pressed, the in
progress LED will illuminate. The complete LED will illuminate after a successful service.

Customer Service Department:
1-905-270-0555 or Toll Free 1-800-841-8810 or email at [email protected]

Maintenance

1. The side grills may build up residue after extended use. This is normal.

Wipe off using a soft brush.
2. Empty fluid after each use.

What it Means

Corrective Action

All three lights flashing:
Improper voltage below
11 VDC or above 18 VDC
or component failure.

Right light on solid.
Low fluid or machine
not level.

Center and Right light on

solid. Service time was

less than 8 minutes

(normal cycle is approx,

14 minutes @ 72 F/22C) or
Low fluid level or Machine

not level.

Center light flashing

Service time exceeded 18

minutes (normal cycle is

approximately 14 minutes

@ 72F / 22C).

Center light flashing

Ambient temperature

inside vehicle is lower

that 50F/10C or fluid

temperature is lower than

50F/10C.

Ensure that vehicle is running and A/C is turned on
(if equipped). Disconnect from power & reconnect.
Check vehicles charging system for proper output
and clean terminals.

Drain machine completely and refill. To drain – tilt

forward: fill using new (clean) container.
Ensure that machine is resting on a flat-level

surface. Use positioning level – bubble in the

center – disconnect power cord and reconnect

to reset unit.

Drain machine completely and refill. To drain - tilt

machine forward; fill using new (clean) container.

Disconnect from power and reconnect.
Ensure that machine is resting on a flat-level

surface. Use positioning level – bubble in the

center – disconnect power cord and reconnect

to reset unit.

Sufficient cleaning solution has been used to

warrant a ‘full’ service. Drain machine completely

to prepare for next service.

Store cleaning solution at room temperature.

Adjust interior vehicle temperature (adjust climate

control to increase temp to 72F/22C). Disconnect

from power and reconnect.

Right light flashing

Ambient temperature

inside vehicle is above

120F/50C.

Adjust interior vehicle temperature. Adjust climate

control (run A/C) to lower temp to 72F/22C.

Center and right lights

flashing High current over

5 amps.

Reset machine. Disconnect from power & reconnect.

Contact customer service if problem persists.

All lights flashing

Component failure or

incorrect input voltage.

Reset machine. Disconnect from power and

reconnect. Contact customer service if

problem persists.

CarClean

System

6

Advertising