Before you begin, First time operation – MotorVac COOLANTCLEAN-1000 User Manual

Page 11

Advertising
background image

Before You Begin

First Time Operation

NOTE:

This unit has been tested with water and is ready

for use after receiving the unit & performing the

following priming procedure.

Remember to send in your warranty card to

properly register your machine.



1.

Check the unit’s service hoses, and all external components for damage.

2.

Attach an adapter to the coupler of the service hose.

3.

Fill the unit’s reservoir with 12 quarts (11 liters) of new coolant mixture.
CAUTION, DO NOT MIX DEXCOOL WITH ETHYLENE GLYCOL TYPE
COOLANT. RESULTS WILL “JELL”.

4.

Insert the hose adapter into the fluid tank fill neck.

5.

Adjust control valves to the “Fill-Clean” position.

6.

Attach air supply line to air input valve.

7.

Hold hose wand securely and turn on air valve

. Pump and wand will “pulse”.

8.

Once the pump has been internally lubricated you can set the valves to vacuum and test the
vacuum function.

9.

Insert the wand into a bucket of fluid, turn the control valves to vacuum and turn on the air valve.
Unit should draw fluid out of the bucket and pump it into the Used/Waste fluid tank. Turn air off.

10.

Turn the control valves to FILL-USED, insert the wand into a fluid capture container and turn the
air valve on. Unit should pump fluid for used fluid tank out of the service hose. Unit is now
“tested”.

11.

The unit is now ready to perform a service. See service instructions for procedure.

NOTE:

This procedure should be performed BEFORE

operating the unit for the first time or any time

the unit’s reservoir tank is completely emptied.







Advertising