Theory of Operation

Detailed descriptions of the various operations, valves and indicators that make up the
COOLANTCLEAN 1000’s control panel are listed below.

3- Control valves:


When the valves are in the VACUUM position .

(And unit connected to a vehicle) The unit will apply vacuum thru the “Green” hose when the air

control valve is turned on and the regulator is adjusted to adequate pressure.

When the valves are in the HOLD position:

After maximum vacuum has been achieved (24 inch’s of vacuum/ top hose collapsed) you can
turn the #3 valve to the ‘HOLD” position. This allows for system leak tests after repairs have been
completed on a vehicle.


When the valves are in the FILL-CLEAN position:

The unit will pump New coolant from the clean fluid tank out of the “Green” hose.


When the valves are in the FILL-USED position:

The unit will pump used fluid from the used/waste fluid tank out of the ”Green” hose. Used to refill

an engine with used fluid after an engine repair has been completed or to empty the waste fluid

into a recycle tank.