INSTRUCTION BULLETIN

Flomax 30 - Self Priming Single Seal Pumpak

Overview:

These instructions pertain to single seal Flomax 30

pump end installation and assembly. Your Flomax

pump may have included a driver such as close-

coupled electric motor, or engine that will hereafter

be referred to as the driver.

PUMPAK ASSEMBLY: (pump end suitable for

mounting to various drivers).

1.

Loosen the drive sleeve clamp.

2.

Slide the pump onto the driver by hand. This

should not require extreme force.

3.

Install and tighten fasteners (4 screws) into the

pump adaptor securing the driver.

4.

Tighten the drive sleeve clamp nuts to 20 - 26 ft-

lbs.

5.

Remove the metal shim strap that spaces the

impeller by pulling it out of the discharge.

6.

Rotate the shaft to ensure that the pump rotates

freely before putting the pump into service.

INSTALLATION:

Optimum performance can be attained by placing the

pump as close to the liquid source as possible.

Secure the pump by mounting it to a foundation or

base plate.

Hose or pipe can be used on the suction and

discharge. The suction line must not be reduced in

size. If hose is used, reinforced non-collapsible type

is recommended. The discharge line must be rated to

the maximum pressure developed by the pump.

Avoid kinks in the hose and unnecessary restrictions

that may affect pump performance.

All pipe connections must be sealed with adequate

thread sealant. A small air leak in the suction line

will affect priming performance. If a throttling valve

is used to adjust the flow rate, it should be mounted

to the discharge piping only - never in the suction.

A large low restriction de-watering type strainer must

be used whenever there are solids present in the

liquid source.

OPERATION:

Fill the pump with liquid prior to starting through a

fitting on the discharge piping. The pump housing

should be completely full. If the pump has a

discharge valve it must be fully open to expel air

during priming at initial start-up. Long horizontal

suction lines require extra time to prime, 2 additional

minutes for every 10 feet of horizontal run.

Start the pump driver. The pump will prime the

suction hose and establish flow in about 5 minutes,

more or less, depending upon the lift distance and

length of horizontal run. After prime, the pump will

perform to its full flow capability.

After the initial prime, the pump will retain liquid in

the housing and may not need to be refilled after

shutdown and restart even if the suction pipe has air

in it.