Electrical – Detroit Radiant Products Company BAH Series User Manual
Page 3
A
B
L1
L2 (or Neutral)
FROM PANEL
BLACK
L2
L1
HEATER
THERMOSTAT
BLACK
HEATER
L2
L1
A
THERMOSTAT
B
FROM PANEL
L1
L2
B
A
BLACK
WHITE
ELECTRICAL
The heater, when installed, must be electrically grounded in accordance with the Canadian Electrical Code C22.1
(latest edition).
Applications in Canada must conform to the Canadian Electrical Code C22.1 (latest edition) when an external
electrical source is used.
Applications in United States must conform to the National Electrical Code ANSI/NFPA 70 (latest edition).
Under no circumstance is the electrical supply line to the heater to provide any assistance in the suspension of the
heater.
Neither the electrical supply line nor sprinkler heads shall be located within the minimum clearances to combustibles.
Refer to rating label on heater for the required amperage rating.
TYPICAL 120 volt INSTALLATION FOR
SINGLE LINE BREAK THERMOSTAT
Single Phase
TYPICAL 240, 208 volt INSTALLATION FOR
DOUBLE LINE BREAK THERMOSTAT
Single Phase
3