Maintenance and servicing

4

Maintenance and servicing table

B

ef

or

e e

v

er

y

commissioning

A

t end of w

or

k

W

eek

ly

Y

ear

ly

A

ft

er faults

A

ft

er damage

Wall saw

u Retighten loose bolts and nuts (re-

fer to the tightening torque specifi -
cations)

X

X

X

Lock unit

u Clean latching recesses and guide

grooves

X

X

X

X

u Lubrication

X

X

X

Guide rollers

u Check the bearing clearance for wear

X

X

X

X

u Clean

X

X

X

X

u Replace

X

Swivel arm

u Clean with water

X

u Check the saw blade uptake for wear

X

X

X

u Replace the gear oil

Every 100 h

Feed motor

u Check cleanliness

X

X

X

X

Drive motor

u Check cleanliness

X

X

X

X

Water supply

u Check the water line for cleanliness

and leak-tightness

X

X

X

u Blow out water

X

Saw blade

u Clean with water

X

u Check for wear

X

X

X

X

Service

u To be performed by TYROLIT Hydros-

tress AG or an authorised workshop

After 100 / 300 / 500 / 700 hours