Aiphone TC-NMD TC-20MD User Manual

Master station with selective door release, Supplement to tc-m instructions

Advertising
background image

n

Master Station with Selective Door Release

TC-10MD 10-Call Master

TC-20MD 20-Call Master

- SUPPLEMENT TO TC-M INSTRUCTIONS -

The TC-MD Intercom and Selective Door Control System is designed for communication between a central master
station and remote door stations. The TC-MD adds door release to the standard TC-M system. All information
regarding installation other than the external control functions is included in the TC-M instructions. In addition to
communication to remote locations, the Master Station can selectively release the corresponding door strike or
maglock.

WIRING DIAGRAM: SYSTEM USED FOR SELECTIVE DOOR RELEASE

Individual Components for System:
TC-nMD

Master station with selective contact output capability (10, 20)

RY-PA

Relay for selective output (1 per station requiring external contact)

PS-1820UL

18V DC, 2A Power Supply

TB-AD1

1 Audio Door Adaptor

TB-AD10

10 Audio Door Adaptor

TB-ADM10

10 Video Door Adaptor

IMPORTANT:
1. RY-PA must be used for each selective contact to

isolate AC voltage from the intercom circuit.

2.

Extra contact connections and L are on the
external terminal block.

Pg. 1

TC-MD TERMINAL DEFINITIONS:
+

Power input (18V DC or 16V AC)

-

Negative

1~10

Station number

E

Common communication

M,C

Master-to-Master communication

T

Transmit to door station

R

Receive from door station

S, S

Output to call extension speaker

SEPARATE TERMINAL BLOCK LOCATED INSIDE MASTER:
1~10 (20) Selective negative for each channel
L

Common Positive output for selective closure

TC-10MD

+

-

PS-1820UL

TB-AD1

For Door #9

1
2

IE/IF Door

Station

1
2

N

T

R

+

-

1
2

N

T

R

+

-

1
2
3
~
9

10

E

T

R

12+

12-

M

C

AC/

DC

Input

TB-AD1

For Door #10

1
2

IE/IF Door

Station

Door Release button

Located below

TRANSFER button.

TC-20MD

x x

RY-PA

#1

RY-PA

#9

RY-PA

#10

BLK

BLK

BLK

YEL

YEL

YEL

Relays are activated
when the door
release button is
being pressed while
a station button is
selected.

Momentary Closure for Station #1

To convert RY-PA to N/C (normally
closed) contact: Move one yellow wire
from "NO" to "NC". (Internal
modification, soldering required.)

AC Power

for Door

Releases

Common for each closure

Momentary Closure for Station #9

Momentary Closure for Station #10

1
~
9

10

L