WIRING DIAGRAM: SYSTEM USED FOR DUAL FUNCTION OF EXTRA CONTACTS

Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071

OPERATION:
* POWER SWITCH ON THE BACK OF THE MASTER MUST BE ON FOR SYSTEM TO BE OPERABLE.
** DOOR RELEASE BUTTON IS LOCATED BELOW THE "TRANSFER" BUTTON ON THE MASTER.

1. When a station calls in, pick up the handset and press the selector button corresponding to the lit LED.
2. Speak to the person at the remote station through the handset. The person at the remote station

speaks hands free.

3. To release the door at the calling party's location, press the "door release" button while still in

communication with the calling station. This will activate the corresponding relay as long as the button is
being held, which will activate the door release mechanism.

4. If both selective door release and a constant closure are used on a channel, the device connected to

the "constant closure" relay will be on as long as the channel is selected. The "momentary closure"
will only be active when the door release button is pressed.

5. When the conversation is completed, hang up the handset.

SPECIFICATIONS
Power Source:

18V DC or 16V AC at master. Use PS-1820UL or 16V AC Transformer (Not supplied by Aiphone)
or AC Transformer (16V AC, 10VA or greater).

Communication:

Handset at master
Hands free at sub station

Calling:

Master to sub: By voice only.
Sub to master: Call button on sub activates tone and LED at master

Wiring:

2 conductors homerun from door to door station adaptor.
Four (4) common wires plus one (1) individual wire per station from door adaptor to Master.
Use Aiphone #812202 (2 cond., 22AWG) or #812206 (6 cond., 22AWG) wire.

Wiring Distance:
Door to Adaptor:

500' with 22AWG; 1,200' with 18AWG.

Adaptor to Master:

210' with 22AWG; 495' with 18AWG.

For additional information about this system,

please refer to the TC-M instructions.

1

L

2

RY-PA

#1

BLK

12+

12-

RY-PA

#2

In TC-MD Master

RY-PA

#1

RY-PA

#2

BLK

BLK

BLK

YEL

Momentary closure #1

YEL

Constant closure #1

YEL

Momentary
closure #2

YEL

Constant
closure #2

Equipment for each station that requires
both a constant closure and momentary
closure when a channel is selected:
2 RY-PA relays
1 Diode (1N4001)

DUAL FUNCTIONS FROM EACH CHANNEL:

Terminal Block Inside Master