Special packages, Observation tubes, Features application – Nova-Tech Atago AP-300 Series Polarimeter User Manual

Page 3: Temperature control, No temperature control, Example of angle of rotation display, Automatic polarimeter

Advertising
background image

Type A

● AP-300 (including accessories)

● Jacketed flow tube with funnel and

● temperature sensor for jacket (200mm-approximate volume 15ml)

● Inner Lid (For Tube 200mm)
* Circulating Constant Temperature Bath 60-C3

(Cat.No.1921) sold separately.

Temperature Control

Cat.No.5296

Type A

● AP-300 (including accessories)

● Unjacketed flow tube with funnel (200mm-approximate volume 15ml)

● Inner Lid (For Tube 200mm)

No Temperature Control

Cat.No.5297

Type B

● AP-300 (including accessories)

● Jacketed flow tube and temperature sensor for jacket
(100mm-approximate volume 10ml)

● Quartz Control Plate (8°, 17°, or 34°)

● Digital printer DP-AD

● Printer paper for DP-AD

● Ribbon cassette for DP-AD

● Circulating Constant Temperature Bath 60-C3 (Cat.No.1921)

Temperature Control

Cat.No.5294

Type C

● AP-300 (including accessories)

● Quartz Control Plate (8°, 17°, or 34°)

● Digital printer DP-AD

● Printer paper for DP-AD

● Ribbon cassette for DP-AD

No Temperature Control

Cat.No.5295

Type D

Options other than above mentioned 4 types are available.
Contact your nearest ATAGO representative for details.

Features

Application

Easy To Use: Simply place an observation tube

in the sample chamber of the AP-300 and press
START key

The minimum angle of rotation is 0.01°, the

minimum International Sugar Scale is 0.01°Z

Automatic Temperature Compensation Function

for International Sugar Scale with a range
between 18°C and 30°C

Conforms with ICUMSA standards

Built in memory stores the 30 most recent

measurement readings

Out-of-range measurements are indicated

instantly by graphic display

The AP-300 offers ease of use with a very

competitive price

Compact and space saving

Average Measurement Value is Displayed!

Password Function as necessary for ISO
Standard!

Measures the specific optical rotation of

medical agents

Measures the concentration of optically active

substances found in fragrance materials or
chemical compositions

Measures the international sugar scale and the

purity of sugar

Identifies the attributes of inverted sugar, etc.

Measures the specific optical rotation or the

concentration of optically active substances

Jacketed flow tube

Jacketed flow tube
with funnel

Features

Application

Example of angle of rotation display

Example of angle of rotation display

Observation tubes

Special Packages

ATAGO has prepared 4different AP-300 packages.

Automatic Temperature
Compensation Function for
International Sugar Scale

ICUMSA compliant

NEW

NEW

MAY.12, 2011 07:10

MAY.12, 2011 07:10

Explanation of measurements display

Angle of rotation
The angle of rotation is the basic numeric value measured by
polarimeters, and changes depending on the concentration of the
solution, the length of the observation tube, temperature, and/or the
measurement wavelength. It is symbolized by "

α

" and indicated in "

°

."

International Sugar Scale
The International Sugar Scale is indicated in "

°Z

."

The measurement value of 26g of sucrose in 100ml of sucrose solution
in a 200mm observation tube is 100°Z. This measurement value is
commonly used in the sugar manufacturing industry, and is usually
temperature-compensated to the reference temperature of 20°C (68°F).
The AP-300 can display the measurement value with or without temperature
compensation (Automatic Temperature Compensation, "

ATC

").

Specific Rotation
The Specific Rotation is a numeric value unique to each substance. By
definition, the specific rotation value is equivalent to the angle of
rotation obtained by a measuring a solution of 100% concentration in a
100mm observation tube (although such a measurement is actually not
practical).
Specific rotation is symbolized by "

[α]

" and indicated in "

°

."

Concentration
The Concentration is the density of a liquid solution made by dissolving
an optically active substance in water or alcohol. It is indicated in
"

g/100ml

."

Purity
The Purity is the proportion of sucrose compared to the soluble solid
content in a sample. It is indicated in "

%

." To measure the purity, input

the Brix value of the sample (which can be obtained by using an ATAGO
refractometer) into the AP-300 before taking a measurement.

Recommended for sugar industry

Recommended for pharmaceutical industry

RE-72001 : Observation tube 100mm long OT-100(A)

RE-72002 : Observation tube 200mm long OT-200(A)

RE-72036 : Jacketed flow tube 50mm

RE-72034 : Jacketed flow tube 100mm

RE-72035 : Jacketed flow tube 200mm

RE-72033 : Jacketed flow tube with funnel 100mm

RE-72032 : Jacketed flow tube with funnel 200mm

RE-72037 : Unjacketed flow tube with funnel 100mm

RE-72038 : Unjacketed flow tube with funnel 200mm

RE-72042 : Unjacketed small volume observation

tube 10mm long

RE-76015 : Sample chamber cover for Flow Cell
(Cover

only)

RE-76016 : Inner lid for 100mm tube

RE-76017 : Inner lid for 200mm tube

RE-76018 : Inner lid for 50mm tube

* To use the flow tubes, the sample chamber RE-76015

and a inner lid matching the size of the tube will be
necessary to be purchased.

* To use the flow tubes, the sample chamber RE-76015

and a inner lid matching the size of the tube will be
necessary to be purchased.

Measurement

wavelength

( )

Measurement

temperature

(TEMP)

Type of

sample tube

(TUBE)

Measurement

reading

Date and time

Mode

Name of

scale

Length of

sample tube

(L)

Operation

keys

Automatic

Polarimeter

Advertising