Nova-Tech Atago RX-i Series Refractometer User Manual

Digital refractometers, 4 measurement mode options, Accessories

Advertising
background image

4 measurement mode options

Digital Refractometers

T h e wo r l d ' s h i g h e s t s t a n d a r d o f t e c h n o l o g y

n ow ava i l a bl e w i t h t o u c h s c r e e n .

ATAG O t a k i n g r e f ra c t o m e t e r s t o t h e n ex t l eve l .

T h e wo r l d ' s h i g h e s t s t a n d a r d o f t e c h n o l o g y

n ow ava i l a bl e w i t h t o u c h s c r e e n .

ATAG O t a k i n g r e f ra c t o m e t e r s t o t h e n ex t l eve l .

Accessories

Funnel-type Flow Cell

Save time with the flow cell! No
need to clean the prism between
measurements.

[RE-56172] RX-5000i, RX-5000i-Plus

[RE-56173] RX-7000i

Digital Printer DP-AD

Cat.No. 3123 DP-AD

For printing on regular paper.

Printing method : Dot impact
Po w e r s u p p l y : AC adaptor

(AC 100V to 240V)

Power consumption : 7VA
Dimensions & weight : 11 Ч 18 Ч 9cm, 470g

(Main unit only)

Digital Printer DP-63

Cat.No. 3118 DP-63

For printing on thermal paper.

Printing method : Thermal dot
Po w e r s u p p l y : AC adaptor

(AC 100V to 240V)

Power consumption : 13VA
Dimensions & weight : 17 Ч 16 Ч 7cm, 580g

(Main unit only)

Sucrose Solution

(calibration certificate optional)

Regular inspection of the RX-i unit is
highly recommended. Use one of the
following solutions to confirm the
calibration.

[RE-111001] 10% sucrose solution (±0.01%)

[RE-112001] 20% sucrose solution (±0.01%)

[RE-113001] 30% sucrose solution (±0.01%)

[RE-114002] 40% sucrose solution (±0.02%)

[RE-115002] 50% sucrose solution (±0.02%)

Shelf life is 10 days.

Model

Model

Measurement items and ranges

Measurement items and ranges

Minimum indication

Minimum indication

Measurement accuracy

Measurement accuracy

*repeatability

1 : When measuring a standard sucrose solution of up to 50% Brix or standard refractive index solution in MODE-1 at 20˚C.
2 : Factory default setting.

Refractive Index (nD) : 1.32422 to 1.58000
B r i x : 0.000 to 100.000%
(Automatic Temperature Compensation)
User scale : 100

nD

: 0.00001

Brix : 0.005%
(The third decimal place is 0 or 5.)
Temp : 0.01˚C

nD :

±0.00002

*±0.00001

Brix : ±0.010% *±0.010% 1
Temp : ±0.05˚C

Refractive Index (nD) : 1.32422 to 1.58000
B r i x : 0.00 to 100.00%
(Automatic Temperature Compensation)
User scale : 100

nD

: 0.00001

Brix : 0.01%
Temp : 0.01˚C

nD :

±0.00004

*±0.00002

Brix : ±0.03%

*±0.01% 1

Temp : ±0.05˚C

Refractive Index (nD) : 1.32422 to 1.70000
B r i x : 0.00 to 100.00%
(Automatic Temperature Compensation)
User scale : 100

nD

: 0.00001 (0.0001) 2

Brix : 0.01% (0.1%) 2
Temp : 0.01˚C

nD :

±0.0001 *±0.00005

Brix ±0.1%

*±0.02% 1

Temp : ±0.05˚C

Application examples

Refractive Index is a common quality standard
measure for pharmaceutical or chemical products.
Measurements need to be taken at a constant
temperature, commonly 20˚C, 25˚C, and 40˚C. The
RX-i series are equipped with the internal Peltier
Thermo-Module, and measurement starts once
the target temperature is reached. Thermo-
Module, and measurement starts once the target
temperature is reached.

The concentrations of industrial solutions are
often monitored. Examples include water-based
cutting oils and cleaning solutions, hydrogen
peroxide, coolants, and alcohol solutions.
Although the Brix scale is commonly used, user
scales can also be programmed to display
converted sample values.

Brix is measured for quality control purposes in
the food and beverage industries.

For maximum accuracy

Displays the measurement value once
the sample reaches the target
temperature.

Displays the measurement value once a
certain level of sample stability is
achieved.

Measures refractive index and
temperature at fixed intervals and
displays the estimated measurement
value at the target temperature.

Provides an option to turn the thermo-
module off. Without temperature control,
the measurement value is displayed in 4
seconds after the START key is pressed.

For emulsion samples

For fast results

For no temperature control

Refractive Index

Brix

Concentrations

Fragrance and
Food Additives

Pharmaceutical Products

Cosmetics

Petroleum and
Organic Solutions

Oils and Fats

Detergents

Beverages and
Fruit Juice

Jams, Honey,
Liquid Sugar, Syrups

Condiments,
Sauces, Soups

Chemical Solutions

Cutting Oil and
Quenching Oil

Antifreeze and Coolants

Common features

Common features

Measurement system : Optical-refraction critical-angle detection system

Light source : LED

Materials : Sample stage - SUS 316 Prism - Artificial sapphire

Display : 7.5 inch color LCD (touch screen)

Power supply : AC100V to 240V

Power consumption : 50/60Hz, 90VA

Ambient Temperature : 5 to 40˚C

Output terminals : Printer - RS-232C, Computer - USB

Temperature control range : 5.00 to 75.00˚C

Dimensions : 37 Ч 26 Ч 14cm
Weight (Main unit only) : 6.6kg

[RX-5000i, RX-5000i-Plus]

, 7.0kg

[RX-7000i ]

(No lower than 10˚C below the ambient temperature and
no higher than 55˚C above the ambient temperature)

Used for measuring volatile
substances.
Choose either metal or resin.

[RE-56180] MAGIC

™ (metal)

[RE-56185] MAGIC

™ (resin)

[Cat. No. 3275]

[Cat. No. 3276]

[Cat. No. 3279]

For the utmost in customer satisfaction...

ATAGO offers calibration service in conformance
with ISO quality management systems as well as
HACCP, GMP and other standards. The following
three documents will be issued. (Calibration
service is performed at an additional cost.)

Calibration Certificate

Traceability Certificate

Traceability Diagram

MAGIC

* Specifications and appearance are subject to change without notice.

All ATAGO refractometers are designed and manufactured in Japan.

ATAGO products comply with HACCP,
GMP, and GLP system standards.

12070000PP Printed in Japan

Headquarters: The Front Tower Shiba Koen, 23rd Floor
2-6-3 Shiba-koen, Minato-ku, Tokyo 105-0011, Japan
TEL : 81-3-3431-1943 FAX : 81-3-3431-1945
[email protected] http : //www.atago.net/

TEL : 1-425-637-2107 [email protected]

TEL : 91-22-2833-8038 / 8076 [email protected]

TEL : 86 20-38106065 [email protected]

TEL : 662-982-8718-9 [email protected]

TEL : 55 16 3916-6000 [email protected]

TEL : 39 2 36557267 [email protected]

V.04

REGISTERED

ISO9001

Advertising