IntraCore IC3624PWR Layer 2 PoE Switch with Dual Gigabit

3.8 Ethernet Cabling

The cables you need are determined by the existing equipment.

To ensure proper operation when installing the switch into a network, make sure that the current cables are suitable
with either 10/100BaseTX, 10/100/1000BaseT or 1000BaseT operation. Check the following criteria against the
current installation of your network:

•

Cable type: Unshielded twisted pair (UTP) or shielded twisted pair (STP) cables with RJ-45 connectors;
Category 3 or better for 10BaseT and Category 5 or better for 100BaseTX.

•

Protection from radio frequency interference emissions

•

Electrical

surge

suppression

•

Separation of electrical wires (switch related or other) and electromagnetic fields from data based network wiring

•

Safe connections with no damaged cables, connectors, or shields

RJ-45 Connector

When attaching a workstation to the switch, a standard straight-through CAT5 cable may be used.

3.9 Connecting to the Console Port

The DB-9 serial port located on the front panel is used to connect to the switch for out-of-band console configuration.
The on-board configuration program can be accessed from a terminal or a PC running a terminal emulation program.
The pin assignments used to connect to the serial port are provided in the following tables.